Uniform Building Code Standards |
From inside the book
Results 1-3 of 82
Page 570
... Concrete Sec . 26.910 . Samples of freshly mixed concrete from at least three separate batches for each condition of concrete shall be tested in accordance with the methods described in this section . In determining the time of setting ...
... Concrete Sec . 26.910 . Samples of freshly mixed concrete from at least three separate batches for each condition of concrete shall be tested in accordance with the methods described in this section . In determining the time of setting ...
Page 571
... concrete mixture containing the chemical admixture under test and from the reference concrete mixture , the air content of each mixture being as specified for air - entrained concrete in Section 26.908 ( d ) . 4. Length change . Make ...
... concrete mixture containing the chemical admixture under test and from the reference concrete mixture , the air content of each mixture being as specified for air - entrained concrete in Section 26.908 ( d ) . 4. Length change . Make ...
Page 1116
... concrete with a topping ( overlay ) of a different type of concrete . 2. Figure No. 43-9-9B gives information on the fire - resistance ratings of roofs which consist of a base slab of concrete with a topping ( overlay ) of an insulating ...
... concrete with a topping ( overlay ) of a different type of concrete . 2. Figure No. 43-9-9B gives information on the fire - resistance ratings of roofs which consist of a base slab of concrete with a topping ( overlay ) of an insulating ...
Other editions - View all
Uniform Building Code Standards International Conference of Building Officials No preview available - 1979 |
Common terms and phrases
½ inch accordance adhesive admixture aggregate allowable load applied average axis beam bending bolt BUILDING CODE STANDARD cement characteristics coating combination compression members compressive strength concrete concrete masonry units conform connector cross section deck determined diameter dimensions Douglas fir E-rated edge end joints equivalent exceed feet fiber flange glue glued holes joists knots laminations lams length less lumber manufactured material maximum measured medium method minimum modulus of elasticity moisture content mortar nominal panel parallel percent permitted perpendicular piece pitch plate plywood portland cement pounds per square pozzolan procedures ratio requirements roof sample sapwood shakes shear shear strength sheet slope of grain spaced span specified splits square inch steel stiffeners stress Structural surface Table temperature tensile tensile strength tension laminations test specimens thickness Type U.B.C. Standard Uniform Building Code values veneer weight welds wide face wire wood failure yield strength Zone