Uniform Building Code Standards |
From inside the book
Results 1-3 of 81
Page 570
concrete and that of the concrete containing the admixture under test shall not
exceed 0 . ... Samples of freshly mixed concrete from at least three separate
batches for each condition of concrete shall be tested in accordance with the
methods ...
concrete and that of the concrete containing the admixture under test shall not
exceed 0 . ... Samples of freshly mixed concrete from at least three separate
batches for each condition of concrete shall be tested in accordance with the
methods ...
Page 571
One set of specimens shall be made from the concrete mixture containing the
chemical admixture under test and from the reference concrete mixture , the air
content of each mixture being as specified for air - entrained concrete in Section
26 .
One set of specimens shall be made from the concrete mixture containing the
chemical admixture under test and from the reference concrete mixture , the air
content of each mixture being as specified for air - entrained concrete in Section
26 .
Page 1116
NEGLECT SHADED AREA IN CALCULATION OF EQUIVALENT THICKNESS ( b
) Multicourse Floors and Roofs . 1 . Figure No . 43 - 9 - 9A gives information on
the fireresistance ratings of floors which consist of a base slab of concrete with a
...
NEGLECT SHADED AREA IN CALCULATION OF EQUIVALENT THICKNESS ( b
) Multicourse Floors and Roofs . 1 . Figure No . 43 - 9 - 9A gives information on
the fireresistance ratings of floors which consist of a base slab of concrete with a
...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Other editions - View all
Uniform Building Code Standards International Conference of Building Officials No preview available - 1979 |
Common terms and phrases
accordance aggregate allowable applied assembly average beam bending bolt cement characteristics checks coating combination compression compression stress concrete conform connections construction containing Continued covers cross depth determined diameter dimensions direction distance door edge effective element end joints equal exceed face feet Figure fire flange foot grade grain greater Group holes inches joists knots laminations least length less light limited load located lumber manufacturer material maximum measured medium method moisture nominal panel parallel percent period permitted piece pine pitch placed plate plywood pounds pressure procedures requirements sample Section shear sheet shown side slope sound spaced specified square steel stiffeners strength stress structural surface Table temperature tension test specimens thickness Type U.B.C. Standard Uniform Building Code unit values weight welds wide width wire wood Zone