Uniform Building Code Standards |
From inside the book
Results 1-3 of 67
Page 47
... construction and adapted for use in masonry exposed to weathering , provided they are burned to the normal maturity ... construction tile are tile designed to be placed in the wall with axes of the cells vertical . Side - construction ...
... construction and adapted for use in masonry exposed to weathering , provided they are burned to the normal maturity ... construction tile are tile designed to be placed in the wall with axes of the cells vertical . Side - construction ...
Page 523
... construction . Moderate sulfate resistance or moderate heat of hydration or both may be specified by adding the ... construction . Type IP - A - Air - entraining portland - pozzolan cement for use in general concrete construction . Type ...
... construction . Moderate sulfate resistance or moderate heat of hydration or both may be specified by adding the ... construction . Type IP - A - Air - entraining portland - pozzolan cement for use in general concrete construction . Type ...
Page 1089
... construction . The ceiling - floor assembly shall be representative of the type of construction ( combusti- ble , noncombustible ) and the fire - endurance time period for which classification is desired , as to materials , workmanship ...
... construction . The ceiling - floor assembly shall be representative of the type of construction ( combusti- ble , noncombustible ) and the fire - endurance time period for which classification is desired , as to materials , workmanship ...
Other editions - View all
Uniform Building Code Standards International Conference of Building Officials No preview available - 1979 |
Common terms and phrases
½ inch accordance adhesive admixture aggregate allowable load applied average axis beam bending bolt BUILDING CODE STANDARD cement characteristics coating combination compression members compressive strength concrete concrete masonry units conform connector cross section deck determined diameter dimensions Douglas fir E-rated edge end joints equivalent exceed feet fiber flange glue glued holes joists knots laminations lams length less lumber manufactured material maximum measured medium method minimum modulus of elasticity moisture content mortar nominal panel parallel percent permitted perpendicular piece pitch plate plywood portland cement pounds per square pozzolan procedures ratio requirements roof sample sapwood shakes shear shear strength sheet slope of grain spaced span specified splits square inch steel stiffeners stress Structural surface Table temperature tensile tensile strength tension laminations test specimens thickness Type U.B.C. Standard Uniform Building Code values veneer weight welds wide face wire wood failure yield strength Zone