... Covers the fire , life and structural safety aspects of all buildings and related structures . Uniform Building Code Standards . Presents in a compact and concise manner national test , material and special design standards referred to ...
... Covers the fire , life and structural safety aspects of all buildings and related structures . Uniform Building Code Standards . Presents in a compact and concise manner national test , material and special design standards referred to ...
Page 985
... Covers . An enclosure cover of an air - sampling - type detector shall be hinged , sliding , pivoted or similarly attached if : ( 1 ) it provides ready access to fuses or any other overcurrent protective device , the normal functioning ...
... Covers . An enclosure cover of an air - sampling - type detector shall be hinged , sliding , pivoted or similarly attached if : ( 1 ) it provides ready access to fuses or any other overcurrent protective device , the normal functioning ...
Page 1106
... covers with 1 - inch - long Type S screws spaced 1 inch from the wallboard edge and 8 inches on center . For such ... covers shall be fabricated from 0.024 - inch - minimum - thickness galvanized or stainless steel . For four - hour fire ...
... covers with 1 - inch - long Type S screws spaced 1 inch from the wallboard edge and 8 inches on center . For such ... covers shall be fabricated from 0.024 - inch - minimum - thickness galvanized or stainless steel . For four - hour fire ...
Other editions - View all
Uniform Building Code Standards International Conference of Building Officials No preview available - 1979 |
Common terms and phrases
½ inch accordance adhesive admixture aggregate allowable load applied average axis beam bending bolt BUILDING CODE STANDARD cement characteristics coating combination compression members compressive strength concrete concrete masonry units conform connector cross section deck determined diameter dimensions Douglas fir E-rated edge end joints equivalent exceed feet fiber flange glue glued holes joists knots laminations lams length less lumber manufactured material maximum measured medium method minimum modulus of elasticity moisture content mortar nominal panel parallel percent permitted perpendicular piece pitch plate plywood portland cement pounds per square pozzolan procedures ratio requirements roof sample sapwood shakes shear shear strength sheet slope of grain spaced span specified splits square inch steel stiffeners stress Structural surface Table temperature tensile tensile strength tension laminations test specimens thickness Type U.B.C. Standard Uniform Building Code values veneer weight welds wide face wire wood failure yield strength Zone