Uniform Building Code Standards |
From inside the book
Results 1-3 of 74
Page 328
... Distance . Edge distance is the distance from edge of member to center of connector closest to the edge of the member measured perpendicular to the edge . ( See Figures Nos . 25-17-1 and 25-17-2 . ) P B Piece A = End distance . 8 ...
... Distance . Edge distance is the distance from edge of member to center of connector closest to the edge of the member measured perpendicular to the edge . ( See Figures Nos . 25-17-1 and 25-17-2 . ) P B Piece A = End distance . 8 ...
Page 330
... distance , end distance or spacing , the reduced allowable load for each shall be determined separately and the lowest allowable load so determined for any one connector shall apply . Such load reductions are not cumulative . 2. End ...
... distance , end distance or spacing , the reduced allowable load for each shall be determined separately and the lowest allowable load so determined for any one connector shall apply . Such load reductions are not cumulative . 2. End ...
Page 997
... distance will be : Ts 100 Od = Τ WHERE : Od = percent obscuration at distance d . Ts Το = smoke density meter reading with smoke . = smoke density meter reading with clear air . 3. When the percent obscuration per foot is known , the ...
... distance will be : Ts 100 Od = Τ WHERE : Od = percent obscuration at distance d . Ts Το = smoke density meter reading with smoke . = smoke density meter reading with clear air . 3. When the percent obscuration per foot is known , the ...
Other editions - View all
Uniform Building Code Standards International Conference of Building Officials No preview available - 1979 |
Common terms and phrases
½ inch accordance adhesive admixture aggregate allowable load applied average axis beam bending bolt BUILDING CODE STANDARD cement characteristics coating combination compression members compressive strength concrete concrete masonry units conform connector cross section deck determined diameter dimensions Douglas fir E-rated edge end joints equivalent exceed feet fiber flange glue glued holes joists knots laminations lams length less lumber manufactured material maximum measured medium method minimum modulus of elasticity moisture content mortar nominal panel parallel percent permitted perpendicular piece pitch plate plywood portland cement pounds per square pozzolan procedures ratio requirements roof sample sapwood shakes shear shear strength sheet slope of grain spaced span specified splits square inch steel stiffeners stress Structural surface Table temperature tensile tensile strength tension laminations test specimens thickness Type U.B.C. Standard Uniform Building Code values veneer weight welds wide face wire wood failure yield strength Zone