Page 646
... Electrodes . The following electrodes shall be used for arc welding : 1. For connected members both having a specified minimum yield strength greater than 36,000 psi : AWS A5.1 or A5.5 , E70XX AWS A5.17 , F7X - EXXX flux - electrode ...
... Electrodes . The following electrodes shall be used for arc welding : 1. For connected members both having a specified minimum yield strength greater than 36,000 psi : AWS A5.1 or A5.5 , E70XX AWS A5.17 , F7X - EXXX flux - electrode ...
Page 647
... electrode combinations ... Made with E60 series electrodes or F6X - EXXX flux- electrode combinations . . . . 0.6F , .0.9F 0.75F .21,000 psi . 18,000 psi Tension or compression on groove or butt welds shall be the same as those ...
... electrode combinations ... Made with E60 series electrodes or F6X - EXXX flux- electrode combinations . . . . 0.6F , .0.9F 0.75F .21,000 psi . 18,000 psi Tension or compression on groove or butt welds shall be the same as those ...
Page 653
... electrode combinations ..... Made with E60 series electrodes or F6X - EXXX flux - electrode combinations ..... Tension or compression on groove or butt welds shall be the same as those specified for the connected material . 21,000 psi ...
... electrode combinations ..... Made with E60 series electrodes or F6X - EXXX flux - electrode combinations ..... Tension or compression on groove or butt welds shall be the same as those specified for the connected material . 21,000 psi ...
Other editions - View all
Uniform Building Code Standards International Conference of Building Officials No preview available - 1979 |
Common terms and phrases
½ inch accordance adhesive admixture aggregate allowable load applied average axis beam bending bolt BUILDING CODE STANDARD cement characteristics coating combination compression members compressive strength concrete concrete masonry units conform connector cross section deck determined diameter dimensions Douglas fir E-rated edge end joints equivalent exceed feet fiber flange glue glued holes joists knots laminations lams length less lumber manufactured material maximum measured medium method minimum modulus of elasticity moisture content mortar nominal panel parallel percent permitted perpendicular piece pitch plate plywood portland cement pounds per square pozzolan procedures ratio requirements roof sample sapwood shakes shear shear strength sheet slope of grain spaced span specified splits square inch steel stiffeners stress Structural surface Table temperature tensile tensile strength tension laminations test specimens thickness Type U.B.C. Standard Uniform Building Code values veneer weight welds wide face wire wood failure yield strength Zone