Uniform Building Code Standards |
From inside the book
Results 1-3 of 79
Page 84
Splits — Equal in length to one and one - half times the width of the piece . Stain -
Stained sapwood . Firm heart stain or firm red heart not limited . Unsound wood -
Not permitted in thicknesses over 2 inches but in 2 - inch thickness , heart ...
Splits — Equal in length to one and one - half times the width of the piece . Stain -
Stained sapwood . Firm heart stain or firm red heart not limited . Unsound wood -
Not permitted in thicknesses over 2 inches but in 2 - inch thickness , heart ...
Page 152
Characteristics and limiting provisions are : Stained sapwood ; splits — three
fourths the thickness ; seasoning checks — single or opposite each other with a
sum total equal to one half the thickness of the piece ; heavy tom grain ; slope of ...
Characteristics and limiting provisions are : Stained sapwood ; splits — three
fourths the thickness ; seasoning checks — single or opposite each other with a
sum total equal to one half the thickness of the piece ; heavy tom grain ; slope of ...
Page 224
The lateral resistance design values for loads of normal duration equals :
average proportional limit ( 1 . ... 1007 ( k ) 7 B ( i ) b shall equal or exceed the
following : Tension Lamination Grade Grade Substituted For Test Value Fifth
Percentile 30 ...
The lateral resistance design values for loads of normal duration equals :
average proportional limit ( 1 . ... 1007 ( k ) 7 B ( i ) b shall equal or exceed the
following : Tension Lamination Grade Grade Substituted For Test Value Fifth
Percentile 30 ...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Other editions - View all
Uniform Building Code Standards International Conference of Building Officials No preview available - 1979 |
Common terms and phrases
accordance aggregate allowable applied assembly average beam bending bolt cement characteristics checks coating combination compression compression stress concrete conform connections construction containing Continued covers cross depth determined diameter dimensions direction distance door edge effective element end joints equal exceed face feet Figure fire flange foot grade grain greater Group holes inches joists knots laminations least length less light limited load located lumber manufacturer material maximum measured medium method moisture nominal panel parallel percent period permitted piece pine pitch placed plate plywood pounds pressure procedures requirements sample Section shear sheet shown side slope sound spaced specified square steel stiffeners strength stress structural surface Table temperature tension test specimens thickness Type U.B.C. Standard Uniform Building Code unit values weight welds wide width wire wood Zone