Uniform Building Code Standards |
From inside the book
Results 1-3 of 73
Page 20
The fire test structure shall consist of a room 8 feet by 12 feet having a ceiling
height of 8 feet located in an enclosed building . A doorway 2 feet 6 inches by 7
feet 0 inches shall be centered in one of the 8 - foot - long walls of the test
structure .
The fire test structure shall consist of a room 8 feet by 12 feet having a ceiling
height of 8 feet located in an enclosed building . A doorway 2 feet 6 inches by 7
feet 0 inches shall be centered in one of the 8 - foot - long walls of the test
structure .
Page 313
5 inches or less at 6 feet from the butt and in the outer 3 inches of poles having a
circumference of more than 37 . 5 inches at 6 feet from the butt shall be not less
than six rings per inch . EXCEPTION : Poles with four and five rings per inch are ...
5 inches or less at 6 feet from the butt and in the outer 3 inches of poles having a
circumference of more than 37 . 5 inches at 6 feet from the butt shall be not less
than six rings per inch . EXCEPTION : Poles with four and five rings per inch are ...
Page 314
No pole shall have a scar or turpentine face ( southern pine ) located within 2 feet
of the ground line . Turpentine scars need be trimmed only to the extent
necessary to examine for evidence of fungus infection and insect damage . Other
sound ...
No pole shall have a scar or turpentine face ( southern pine ) located within 2 feet
of the ground line . Turpentine scars need be trimmed only to the extent
necessary to examine for evidence of fungus infection and insect damage . Other
sound ...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Other editions - View all
Uniform Building Code Standards International Conference of Building Officials No preview available - 1979 |
Common terms and phrases
accordance aggregate allowable applied assembly average beam bending bolt cement characteristics checks coating combination compression compression stress concrete conform connections construction containing Continued covers cross depth determined diameter dimensions direction distance door edge effective element end joints equal exceed face feet Figure fire flange foot grade grain greater Group holes inches joists knots laminations least length less light limited load located lumber manufacturer material maximum measured medium method moisture nominal panel parallel percent period permitted piece pine pitch placed plate plywood pounds pressure procedures requirements sample Section shear sheet shown side slope sound spaced specified square steel stiffeners strength stress structural surface Table temperature tension test specimens thickness Type U.B.C. Standard Uniform Building Code unit values weight welds wide width wire wood Zone