Page 437
... feet per minute . During drying the specimens shall be placed at least 2 ... 1/16 inch or 0.05 inch . Failure in the wood due to checking or other causes ... hour . This vacuum - pressure cycle shall then be repeated with the test ...
... feet per minute . During drying the specimens shall be placed at least 2 ... 1/16 inch or 0.05 inch . Failure in the wood due to checking or other causes ... hour . This vacuum - pressure cycle shall then be repeated with the test ...
Page 1090
... hour , one and one half hours , two hours or three hours . Hose Stream Test ... 1 % -inch discharge tip of the standard - taper smoothbore pattern without shoulder at the orifice . The water pressure at the base of the nozzle and duration of ...
... hour , one and one half hours , two hours or three hours . Hose Stream Test ... 1 % -inch discharge tip of the standard - taper smoothbore pattern without shoulder at the orifice . The water pressure at the base of the nozzle and duration of ...
Page 1160
... hour fire - resistive rating when tested with veneer plaster in accordance with the requirements of U.B.C. Standard No. 43-1 ... feet to 16 feet with permissible variations of ± 1⁄4 inch from the 1160 47-15 U.B.C. STANDARDS.
... hour fire - resistive rating when tested with veneer plaster in accordance with the requirements of U.B.C. Standard No. 43-1 ... feet to 16 feet with permissible variations of ± 1⁄4 inch from the 1160 47-15 U.B.C. STANDARDS.
Other editions - View all
Uniform Building Code Standards International Conference of Building Officials No preview available - 1979 |
Common terms and phrases
½ inch accordance adhesive admixture aggregate allowable load applied average axis beam bending bolt BUILDING CODE STANDARD cement characteristics coating combination compression members compressive strength concrete concrete masonry units conform connector cross section deck determined diameter dimensions Douglas fir E-rated edge end joints equivalent exceed feet fiber flange glue glued holes joists knots laminations lams length less lumber manufactured material maximum measured medium method minimum modulus of elasticity moisture content mortar nominal panel parallel percent permitted perpendicular piece pitch plate plywood portland cement pounds per square pozzolan procedures ratio requirements roof sample sapwood shakes shear shear strength sheet slope of grain spaced span specified splits square inch steel stiffeners stress Structural surface Table temperature tensile tensile strength tension laminations test specimens thickness Type U.B.C. Standard Uniform Building Code values veneer weight welds wide face wire wood failure yield strength Zone