Uniform Building Code Standards |
From inside the book
Results 1-3 of 75
Page 133
... foot piece ; slight torn or raised grain ; medium skip on back limited to one fourth of the length , medium on edge limited to one third of the length ; light cup ; medium crook ; wane on back , one half the thickness , one sixth the ...
... foot piece ; slight torn or raised grain ; medium skip on back limited to one fourth of the length , medium on edge limited to one third of the length ; light cup ; medium crook ; wane on back , one half the thickness , one sixth the ...
Page 160
... foot by 8 - foot face , with proportional limits for other sizes . They shall also be well matched for color and grain . Patches are limited to three “ router ” patches not exceeding 1 inch in width and 31/2 inches in length . No ...
... foot by 8 - foot face , with proportional limits for other sizes . They shall also be well matched for color and grain . Patches are limited to three “ router ” patches not exceeding 1 inch in width and 31/2 inches in length . No ...
Page 666
... foot , of LH- Series joists . The weight of dead loads , including the joists , must in all cases be deducted to ... foot shown in the tables . The lower figures in this load table are the live loads per linear foot of joist which will ...
... foot , of LH- Series joists . The weight of dead loads , including the joists , must in all cases be deducted to ... foot shown in the tables . The lower figures in this load table are the live loads per linear foot of joist which will ...
Other editions - View all
Uniform Building Code Standards International Conference of Building Officials No preview available - 1979 |
Common terms and phrases
½ inch accordance adhesive admixture aggregate allowable load applied average axis beam bending bolt BUILDING CODE STANDARD cement characteristics coating combination compression members compressive strength concrete concrete masonry units conform connector cross section deck determined diameter dimensions Douglas fir E-rated edge end joints equivalent exceed feet fiber flange glue glued holes joists knots laminations lams length less lumber manufactured material maximum measured medium method minimum modulus of elasticity moisture content mortar nominal panel parallel percent permitted perpendicular piece pitch plate plywood portland cement pounds per square pozzolan procedures ratio requirements roof sample sapwood shakes shear shear strength sheet slope of grain spaced span specified splits square inch steel stiffeners stress Structural surface Table temperature tensile tensile strength tension laminations test specimens thickness Type U.B.C. Standard Uniform Building Code values veneer weight welds wide face wire wood failure yield strength Zone