Uniform Building Code Standards |
From inside the book
Results 1-3 of 59
Page 1149
... gypsum plasters , namely : Gypsum ready - mixed plaster , Gypsum neat plaster , Gypsum neat plaster , Type " R , " Gypsum wood - fibered plaster , and Gypsum gaging plaster for finish coat . Calcined Gypsum Sec . 47.902 . The calcined ...
... gypsum plasters , namely : Gypsum ready - mixed plaster , Gypsum neat plaster , Gypsum neat plaster , Type " R , " Gypsum wood - fibered plaster , and Gypsum gaging plaster for finish coat . Calcined Gypsum Sec . 47.902 . The calcined ...
Page 1172
... gypsum board or gypsum lath with the micrometer at least 1⁄2 inch from cut ends . Take a minimum of six readings at each end of the 48 - inch - wide gypsum board , five readings at each end of the 32 - inch - wide gypsum board or gypsum ...
... gypsum board or gypsum lath with the micrometer at least 1⁄2 inch from cut ends . Take a minimum of six readings at each end of the 48 - inch - wide gypsum board , five readings at each end of the 32 - inch - wide gypsum board or gypsum ...
Page 1187
... gypsum base and the gypsum backing board . The veneer plaster shall not be applied until the veneer base is firmly bonded . Adhesive Application of Gypsum Base to Interior Masonry or Concrete Walls Sec . 47.1912 . Direct adhesive ...
... gypsum base and the gypsum backing board . The veneer plaster shall not be applied until the veneer base is firmly bonded . Adhesive Application of Gypsum Base to Interior Masonry or Concrete Walls Sec . 47.1912 . Direct adhesive ...
Other editions - View all
Uniform Building Code Standards International Conference of Building Officials No preview available - 1979 |
Common terms and phrases
½ inch accordance adhesive admixture aggregate allowable load applied average axis beam bending bolt BUILDING CODE STANDARD cement characteristics coating combination compression members compressive strength concrete concrete masonry units conform connector cross section deck determined diameter dimensions Douglas fir E-rated edge end joints equivalent exceed feet fiber flange glue glued holes joists knots laminations lams length less lumber manufactured material maximum measured medium method minimum modulus of elasticity moisture content mortar nominal panel parallel percent permitted perpendicular piece pitch plate plywood portland cement pounds per square pozzolan procedures ratio requirements roof sample sapwood shakes shear shear strength sheet slope of grain spaced span specified splits square inch steel stiffeners stress Structural surface Table temperature tensile tensile strength tension laminations test specimens thickness Type U.B.C. Standard Uniform Building Code values veneer weight welds wide face wire wood failure yield strength Zone