... GYPSUM WALLBOARD TO WOOD FRAMING Based on Standard Specification C557-73 of the American Society for Testing and Materials Scope See Section 4711 ( c ) , Uniform ... Gypsum Wallboard to Wood Framing Standard Specification C557-73 of the ASTM.
... GYPSUM WALLBOARD TO WOOD FRAMING Based on Standard Specification C557-73 of the American Society for Testing and Materials Scope See Section 4711 ( c ) , Uniform ... Gypsum Wallboard to Wood Framing Standard Specification C557-73 of the ASTM.
Page 1154
... WALLBOARD Based on Standard Specification C36-76a of the American Society for Testing and Materials Scope See Section 4711 ( a ) , Uniform Building Code Sec . 47.1101 . This standard covers gypsum wallboard , designed to be used without ...
... WALLBOARD Based on Standard Specification C36-76a of the American Society for Testing and Materials Scope See Section 4711 ( a ) , Uniform Building Code Sec . 47.1101 . This standard covers gypsum wallboard , designed to be used without ...
Page 1155
... wallboard shall be at least 0.015 inch but not more than 0.075 inch less than the average thickness of the wallboard as determined in accordance with U.B.C. Standard No. 47-17 . ( b ) Width . The nominal width of gypsum wallboard shall ...
... wallboard shall be at least 0.015 inch but not more than 0.075 inch less than the average thickness of the wallboard as determined in accordance with U.B.C. Standard No. 47-17 . ( b ) Width . The nominal width of gypsum wallboard shall ...
Other editions - View all
Uniform Building Code Standards International Conference of Building Officials No preview available - 1979 |
Common terms and phrases
½ inch accordance adhesive admixture aggregate allowable load applied average axis beam bending bolt BUILDING CODE STANDARD cement characteristics coating combination compression members compressive strength concrete concrete masonry units conform connector cross section deck determined diameter dimensions Douglas fir E-rated edge end joints equivalent exceed feet fiber flange glue glued holes joists knots laminations lams length less lumber manufactured material maximum measured medium method minimum modulus of elasticity moisture content mortar nominal panel parallel percent permitted perpendicular piece pitch plate plywood portland cement pounds per square pozzolan procedures ratio requirements roof sample sapwood shakes shear shear strength sheet slope of grain spaced span specified splits square inch steel stiffeners stress Structural surface Table temperature tensile tensile strength tension laminations test specimens thickness Type U.B.C. Standard Uniform Building Code values veneer weight welds wide face wire wood failure yield strength Zone