... installed an easily read sign bearing the inscription : IN CASE OF FIRE , RELEASE RING TO LOWER FIRE CUR- TAIN , with an indicator pointing to the location of the ring . For electric operation there shall be installed push buttons ...
... installed an easily read sign bearing the inscription : IN CASE OF FIRE , RELEASE RING TO LOWER FIRE CUR- TAIN , with an indicator pointing to the location of the ring . For electric operation there shall be installed push buttons ...
Page 1089
... installed in a fire - resisting ceiling - floor assembly on a horizontal large- scale furnace . The area of the ceiling exposed to fire shall be not less than 180 square feet , with neither dimension less than 12 feet . Fire exposure ...
... installed in a fire - resisting ceiling - floor assembly on a horizontal large- scale furnace . The area of the ceiling exposed to fire shall be not less than 180 square feet , with neither dimension less than 12 feet . Fire exposure ...
Page 1179
... installed so that they are all level to within inch in 12 feet . Where main runners are supported directly by hangers , leveling shall be per- formed with the supporting hanger taut . Local kinks or bends shall not be made in hanger ...
... installed so that they are all level to within inch in 12 feet . Where main runners are supported directly by hangers , leveling shall be per- formed with the supporting hanger taut . Local kinks or bends shall not be made in hanger ...
Other editions - View all
Uniform Building Code Standards International Conference of Building Officials No preview available - 1979 |
Common terms and phrases
½ inch accordance adhesive admixture aggregate allowable load applied average axis beam bending bolt BUILDING CODE STANDARD cement characteristics coating combination compression members compressive strength concrete concrete masonry units conform connector cross section deck determined diameter dimensions Douglas fir E-rated edge end joints equivalent exceed feet fiber flange glue glued holes joists knots laminations lams length less lumber manufactured material maximum measured medium method minimum modulus of elasticity moisture content mortar nominal panel parallel percent permitted perpendicular piece pitch plate plywood portland cement pounds per square pozzolan procedures ratio requirements roof sample sapwood shakes shear shear strength sheet slope of grain spaced span specified splits square inch steel stiffeners stress Structural surface Table temperature tensile tensile strength tension laminations test specimens thickness Type U.B.C. Standard Uniform Building Code values veneer weight welds wide face wire wood failure yield strength Zone