Uniform Building Code Standards |
From inside the book
Results 1-3 of 11
Page 1147
... lath designed to be used as a base for the application of gypsum plaster in ac- cordance with the requirements of the Uniform Building Code . Composition Sec . 47.802 . ( a ) Plain Gypsum Lath . Gypsum lath shall consist of a noncombus ...
... lath designed to be used as a base for the application of gypsum plaster in ac- cordance with the requirements of the Uniform Building Code . Composition Sec . 47.802 . ( a ) Plain Gypsum Lath . Gypsum lath shall consist of a noncombus ...
Page 1148
... lath per 1000 square feet shall conform to the requirements set forth in Table No. 47-8 - B . Finish Sec . 47.804 . The surfaces of gypsum lath shall be such that they will readily receive and retain gypsum plaster . The edges and ends ...
... lath per 1000 square feet shall conform to the requirements set forth in Table No. 47-8 - B . Finish Sec . 47.804 . The surfaces of gypsum lath shall be such that they will readily receive and retain gypsum plaster . The edges and ends ...
Page 1172
... lath excluding the tapered , beveled or recessed edges if applicable . The micrometer contact shall be firm but shall not indent the paper . Measure the thickness of the gypsum board or gypsum lath with the micrometer at least 1⁄2 inch ...
... lath excluding the tapered , beveled or recessed edges if applicable . The micrometer contact shall be firm but shall not indent the paper . Measure the thickness of the gypsum board or gypsum lath with the micrometer at least 1⁄2 inch ...
Other editions - View all
Uniform Building Code Standards International Conference of Building Officials No preview available - 1979 |
Common terms and phrases
½ inch accordance adhesive admixture aggregate allowable load applied average axis beam bending bolt BUILDING CODE STANDARD cement characteristics coating combination compression members compressive strength concrete concrete masonry units conform connector cross section deck determined diameter dimensions Douglas fir E-rated edge end joints equivalent exceed feet fiber flange glue glued holes joists knots laminations lams length less lumber manufactured material maximum measured medium method minimum modulus of elasticity moisture content mortar nominal panel parallel percent permitted perpendicular piece pitch plate plywood portland cement pounds per square pozzolan procedures ratio requirements roof sample sapwood shakes shear shear strength sheet slope of grain spaced span specified splits square inch steel stiffeners stress Structural surface Table temperature tensile tensile strength tension laminations test specimens thickness Type U.B.C. Standard Uniform Building Code values veneer weight welds wide face wire wood failure yield strength Zone