Uniform Building Code Standards |
From inside the book
Results 1-3 of 88
Page 105
SLIGHT CROSS GRAIN , slope of grain not more than 1 inch in a length of 15
inches . MEDIUM CROSS GRAIN , slope of grain more than 1 inch in a length of
15 inches , but not more than 1 inch in a length of 8 inches . PITCH POCKET , an
...
SLIGHT CROSS GRAIN , slope of grain not more than 1 inch in a length of 15
inches . MEDIUM CROSS GRAIN , slope of grain more than 1 inch in a length of
15 inches , but not more than 1 inch in a length of 8 inches . PITCH POCKET , an
...
Page 129
25 - 1 - F ; wane on back , two thirds the thickness , one fourth the width , one half
the length or equivalent in an occasional piece ; split one sixth the length ; heavy
pitch over one half the area or two small streaks of massed pitch ; medium , well ...
25 - 1 - F ; wane on back , two thirds the thickness , one fourth the width , one half
the length or equivalent in an occasional piece ; split one sixth the length ; heavy
pitch over one half the area or two small streaks of massed pitch ; medium , well ...
Page 141
2 Factory but cept through checks at end equal in wane may not extend length to
width of piece . Firm red into tongue or groove heart not limited . Grain deviation -
lif D & M or 12 thick . slope of grain limited to 1 " in 10 " of ness of lap if ship ...
2 Factory but cept through checks at end equal in wane may not extend length to
width of piece . Firm red into tongue or groove heart not limited . Grain deviation -
lif D & M or 12 thick . slope of grain limited to 1 " in 10 " of ness of lap if ship ...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Other editions - View all
Uniform Building Code Standards International Conference of Building Officials No preview available - 1979 |
Common terms and phrases
accordance aggregate allowable applied assembly average beam bending bolt cement characteristics checks coating combination compression compression stress concrete conform connections construction containing Continued covers cross depth determined diameter dimensions direction distance door edge effective element end joints equal exceed face feet Figure fire flange foot grade grain greater Group holes inches joists knots laminations least length less light limited load located lumber manufacturer material maximum measured medium method moisture nominal panel parallel percent period permitted piece pine pitch placed plate plywood pounds pressure procedures requirements sample Section shear sheet shown side slope sound spaced specified square steel stiffeners strength stress structural surface Table temperature tension test specimens thickness Type U.B.C. Standard Uniform Building Code unit values weight welds wide width wire wood Zone