... material may be steamed prior to conditioning or treatment for a total period not to exceed two hours ; the temperature shall not exceed 240 ° F . When steam - conditioning is used , material shall be steamed in the cylinder at the ...
... material may be steamed prior to conditioning or treatment for a total period not to exceed two hours ; the temperature shall not exceed 240 ° F . When steam - conditioning is used , material shall be steamed in the cylinder at the ...
Page 1027
... material . Bearings , hinges , etc. , are not acceptable for carrying current between fixed and moving parts . ( d ) Electrical Insulating Material . Material for the mounting of current - carrying parts shall be porcelain , phenolic ...
... material . Bearings , hinges , etc. , are not acceptable for carrying current between fixed and moving parts . ( d ) Electrical Insulating Material . Material for the mounting of current - carrying parts shall be porcelain , phenolic ...
Page 1241
... material . Calculate the moisture content of the material removed from the hole as follows : @ = M - Mo M6 × 100 WHERE : w = percentage of moisture , in material from test hole , = M , moist mass of material from test hole , g , M = dry ...
... material . Calculate the moisture content of the material removed from the hole as follows : @ = M - Mo M6 × 100 WHERE : w = percentage of moisture , in material from test hole , = M , moist mass of material from test hole , g , M = dry ...
Other editions - View all
Uniform Building Code Standards International Conference of Building Officials No preview available - 1979 |
Common terms and phrases
½ inch accordance adhesive admixture aggregate allowable load applied average axis beam bending bolt BUILDING CODE STANDARD cement characteristics coating combination compression members compressive strength concrete concrete masonry units conform connector cross section deck determined diameter dimensions Douglas fir E-rated edge end joints equivalent exceed feet fiber flange glue glued holes joists knots laminations lams length less lumber manufactured material maximum measured medium method minimum modulus of elasticity moisture content mortar nominal panel parallel percent permitted perpendicular piece pitch plate plywood portland cement pounds per square pozzolan procedures ratio requirements roof sample sapwood shakes shear shear strength sheet slope of grain spaced span specified splits square inch steel stiffeners stress Structural surface Table temperature tensile tensile strength tension laminations test specimens thickness Type U.B.C. Standard Uniform Building Code values veneer weight welds wide face wire wood failure yield strength Zone