Page 292
Ice - coated or frozen material may be steamed prior to conditioning or treatment
for a total period not to exceed two hours ; the temperature shall not exceed 240°
F . When steam - conditioning is used , material shall be steamed in the cylinder ...
Ice - coated or frozen material may be steamed prior to conditioning or treatment
for a total period not to exceed two hours ; the temperature shall not exceed 240°
F . When steam - conditioning is used , material shall be steamed in the cylinder ...
Page 295
be not less than that specified for the individual type of material or species . ( 0 )
Determination of Penetration . Penetration shall be determined by boring a
representative number of pieces that are well distributed throughout each charge
.
be not less than that specified for the individual type of material or species . ( 0 )
Determination of Penetration . Penetration shall be determined by boring a
representative number of pieces that are well distributed throughout each charge
.
Page 1027
Operating components and assemblies , such as switches , relays and similar
devices , shall be adequately protected by individual protection or dusttight
cabinets , against fouling by dust or by other material which may affect their
normal ...
Operating components and assemblies , such as switches , relays and similar
devices , shall be adequately protected by individual protection or dusttight
cabinets , against fouling by dust or by other material which may affect their
normal ...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Other editions - View all
Uniform Building Code Standards International Conference of Building Officials No preview available - 1979 |
Common terms and phrases
accordance aggregate allowable applied assembly average beam bending bolt cement characteristics checks coating combination compression compression stress concrete conform connections construction containing Continued covers cross depth determined diameter dimensions direction distance door edge effective element end joints equal exceed face feet Figure fire flange foot grade grain greater Group holes inches joists knots laminations least length less light limited load located lumber manufacturer material maximum measured medium method moisture nominal panel parallel percent period permitted piece pine pitch placed plate plywood pounds pressure procedures requirements sample Section shear sheet shown side slope sound spaced specified square steel stiffeners strength stress structural surface Table temperature tension test specimens thickness Type U.B.C. Standard Uniform Building Code unit values weight welds wide width wire wood Zone