Uniform Building Code Standards |
From inside the book
Results 1-3 of 83
Page 73
... measured and limited at the zone in the length of a structural timber that shows the greatest slope . It shall be measured over a distance sufficiently great to define the general slope , disregarding such short local deviations as ...
... measured and limited at the zone in the length of a structural timber that shows the greatest slope . It shall be measured over a distance sufficiently great to define the general slope , disregarding such short local deviations as ...
Page 74
... measured either by its width on the narrow face between lines parallel to the edge , or by its smallest diameter on ... measured on the wide face . The size of a knot on the wide face is measured by its smallest diameter ( see Figure No ...
... measured either by its width on the narrow face between lines parallel to the edge , or by its smallest diameter on ... measured on the wide face . The size of a knot on the wide face is measured by its smallest diameter ( see Figure No ...
Page 75
... Measured the same as for joists and planks . ( d ) Shakes , Checks and Splits . Shakes are measured at the ends of the piece . The size of a shake is the distance between lines enclosing the shake and parallel to the wide face of the ...
... Measured the same as for joists and planks . ( d ) Shakes , Checks and Splits . Shakes are measured at the ends of the piece . The size of a shake is the distance between lines enclosing the shake and parallel to the wide face of the ...
Other editions - View all
Uniform Building Code Standards International Conference of Building Officials No preview available - 1979 |
Common terms and phrases
½ inch accordance adhesive admixture aggregate allowable load applied average axis beam bending bolt BUILDING CODE STANDARD cement characteristics coating combination compression members compressive strength concrete concrete masonry units conform connector cross section deck determined diameter dimensions Douglas fir E-rated edge end joints equivalent exceed feet fiber flange glue glued holes joists knots laminations lams length less lumber manufactured material maximum measured medium method minimum modulus of elasticity moisture content mortar nominal panel parallel percent permitted perpendicular piece pitch plate plywood portland cement pounds per square pozzolan procedures ratio requirements roof sample sapwood shakes shear shear strength sheet slope of grain spaced span specified splits square inch steel stiffeners stress Structural surface Table temperature tensile tensile strength tension laminations test specimens thickness Type U.B.C. Standard Uniform Building Code values veneer weight welds wide face wire wood failure yield strength Zone