Uniform Building Code Standards |
From inside the book
Results 1-3 of 63
Page 341
International Conference of Building Officials. head diameter of roofing nails shall be plus or minus 10 percent of the nominal head diameter ( mean of two readings 90 degrees apart ) and the head diameters for other nails shall be plus ...
International Conference of Building Officials. head diameter of roofing nails shall be plus or minus 10 percent of the nominal head diameter ( mean of two readings 90 degrees apart ) and the head diameters for other nails shall be plus ...
Page 964
... nails shall be about the center of each horizontal layer board . Vertical rows of nails shall be about the center of each vertical layer of board . Nails in horizontal and vertical rows shall be spaced not more than five times the face ...
... nails shall be about the center of each horizontal layer board . Vertical rows of nails shall be about the center of each vertical layer of board . Nails in horizontal and vertical rows shall be spaced not more than five times the face ...
Page 1194
... nail as specified in Section 47.2007 . The nails shall also be compatible with the joint compound and decoration . Nails shall be neatly formed and free from injurious defects or deformations . Number of Tests Sec . 47.2005 . At least five ...
... nail as specified in Section 47.2007 . The nails shall also be compatible with the joint compound and decoration . Nails shall be neatly formed and free from injurious defects or deformations . Number of Tests Sec . 47.2005 . At least five ...
Other editions - View all
Uniform Building Code Standards International Conference of Building Officials No preview available - 1979 |
Common terms and phrases
½ inch accordance adhesive admixture aggregate allowable load applied average axis beam bending bolt BUILDING CODE STANDARD cement characteristics coating combination compression members compressive strength concrete concrete masonry units conform connector cross section deck determined diameter dimensions Douglas fir E-rated edge end joints equivalent exceed feet fiber flange glue glued holes joists knots laminations lams length less lumber manufactured material maximum measured medium method minimum modulus of elasticity moisture content mortar nominal panel parallel percent permitted perpendicular piece pitch plate plywood portland cement pounds per square pozzolan procedures ratio requirements roof sample sapwood shakes shear shear strength sheet slope of grain spaced span specified splits square inch steel stiffeners stress Structural surface Table temperature tensile tensile strength tension laminations test specimens thickness Type U.B.C. Standard Uniform Building Code values veneer weight welds wide face wire wood failure yield strength Zone