Uniform Building Code Standards |
From inside the book
Results 1-3 of 16
Page 885
... partitions such as walls , floor - ceiling assemblies , doors and other space - dividing elements . This standard ... partition element is expressed in terms of the sound transmission loss . The procedure for determining this quantity is ...
... partitions such as walls , floor - ceiling assemblies , doors and other space - dividing elements . This standard ... partition element is expressed in terms of the sound transmission loss . The procedure for determining this quantity is ...
Page 886
... partition to the sound power transmitted through and radiated by the partition . The unqualified term denotes that the incident field is diffuse . SOUND TRANSMISSION COEFFICIENT ( 7 ) OF A PARTITION is the frac- tion of incident sound ...
... partition to the sound power transmitted through and radiated by the partition . The unqualified term denotes that the incident field is diffuse . SOUND TRANSMISSION COEFFICIENT ( 7 ) OF A PARTITION is the frac- tion of incident sound ...
Page 906
... partition type . Special mention shall be made of unusual size of test partitions , unusual size or shape of the test rooms , or other irregularity which may be expected to make the measured results differ significantly from other field ...
... partition type . Special mention shall be made of unusual size of test partitions , unusual size or shape of the test rooms , or other irregularity which may be expected to make the measured results differ significantly from other field ...
Other editions - View all
Uniform Building Code Standards International Conference of Building Officials No preview available - 1979 |
Common terms and phrases
½ inch accordance adhesive admixture aggregate allowable load applied average axis beam bending bolt BUILDING CODE STANDARD cement characteristics coating combination compression members compressive strength concrete concrete masonry units conform connector cross section deck determined diameter dimensions Douglas fir E-rated edge end joints equivalent exceed feet fiber flange glue glued holes joists knots laminations lams length less lumber manufactured material maximum measured medium method minimum modulus of elasticity moisture content mortar nominal panel parallel percent permitted perpendicular piece pitch plate plywood portland cement pounds per square pozzolan procedures ratio requirements roof sample sapwood shakes shear shear strength sheet slope of grain spaced span specified splits square inch steel stiffeners stress Structural surface Table temperature tensile tensile strength tension laminations test specimens thickness Type U.B.C. Standard Uniform Building Code values veneer weight welds wide face wire wood failure yield strength Zone