Uniform Building Code Standards |
From inside the book
Results 1-3 of 81
Page 165
es 1 / 8 inch deep and 1 inch long shall be rated as 0 percent wood failure . ( d )
All Other Grades of Interior - type Plywood . A panel shall be classed as failing if
more than two of the five test specimens fail . The material represented by the ...
es 1 / 8 inch deep and 1 inch long shall be rated as 0 percent wood failure . ( d )
All Other Grades of Interior - type Plywood . A panel shall be classed as failing if
more than two of the five test specimens fail . The material represented by the ...
Page 405
Dry tension wood failure requirements regardless of species shall average not
less than 80 percent except tests averaging at least 10 , 000 pounds per square
inch in tension shall have not less than 70 percent . The minimum requirement for
...
Dry tension wood failure requirements regardless of species shall average not
less than 80 percent except tests averaging at least 10 , 000 pounds per square
inch in tension shall have not less than 70 percent . The minimum requirement for
...
Page 908
International Conference of Building Officials. TABLE NO . 37 - 1 - A - FIRECLAY
AND HIGH - ALUMINA REFRACTORY BRICK CLASS TYPE PANEL SPALLING
LOSS , MMX . , PERCENT HOT LOAD SUBSIDENCE , MAX . , PERCENT MODU
...
International Conference of Building Officials. TABLE NO . 37 - 1 - A - FIRECLAY
AND HIGH - ALUMINA REFRACTORY BRICK CLASS TYPE PANEL SPALLING
LOSS , MMX . , PERCENT HOT LOAD SUBSIDENCE , MAX . , PERCENT MODU
...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Other editions - View all
Uniform Building Code Standards International Conference of Building Officials No preview available - 1979 |
Common terms and phrases
accordance aggregate allowable applied assembly average beam bending bolt cement characteristics checks coating combination compression compression stress concrete conform connections construction containing Continued covers cross depth determined diameter dimensions direction distance door edge effective element end joints equal exceed face feet Figure fire flange foot grade grain greater Group holes inches joists knots laminations least length less light limited load located lumber manufacturer material maximum measured medium method moisture nominal panel parallel percent period permitted piece pine pitch placed plate plywood pounds pressure procedures requirements sample Section shear sheet shown side slope sound spaced specified square steel stiffeners strength stress structural surface Table temperature tension test specimens thickness Type U.B.C. Standard Uniform Building Code unit values weight welds wide width wire wood Zone