Uniform Building Code Standards |
From inside the book
Results 1-3 of 65
Page 19
... placed across the ledges of the test chamber . A 20 - inch - wide by 1 - foot - long piece of 1 / 4 - inch - thick asbestos - cement board is to be placed at the fire end of the test chamber to complete the 25 - foot tunnel length . The ...
... placed across the ledges of the test chamber . A 20 - inch - wide by 1 - foot - long piece of 1 / 4 - inch - thick asbestos - cement board is to be placed at the fire end of the test chamber to complete the 25 - foot tunnel length . The ...
Page 855
... placed so that it is centered laterally with respect to the verticai joint in the test panel , and with the upper edge of the brand located 3 inches above the horizontal joint in the test deck . B. Class B. A brand is to be placed on ...
... placed so that it is centered laterally with respect to the verticai joint in the test panel , and with the upper edge of the brand located 3 inches above the horizontal joint in the test deck . B. Class B. A brand is to be placed on ...
Page 880
... placed under the stairway identification in 1 - inch - high block lettering with 4 - inch stroke ( roof access or no roof access ) . 4. The floor level number shall be placed in the middle of the sign in 5 - inch - high lettering with 4 ...
... placed under the stairway identification in 1 - inch - high block lettering with 4 - inch stroke ( roof access or no roof access ) . 4. The floor level number shall be placed in the middle of the sign in 5 - inch - high lettering with 4 ...
Other editions - View all
Uniform Building Code Standards International Conference of Building Officials No preview available - 1979 |
Common terms and phrases
½ inch accordance adhesive admixture aggregate allowable load applied average axis beam bending bolt BUILDING CODE STANDARD cement characteristics coating combination compression members compressive strength concrete concrete masonry units conform connector cross section deck determined diameter dimensions Douglas fir E-rated edge end joints equivalent exceed feet fiber flange glue glued holes joists knots laminations lams length less lumber manufactured material maximum measured medium method minimum modulus of elasticity moisture content mortar nominal panel parallel percent permitted perpendicular piece pitch plate plywood portland cement pounds per square pozzolan procedures ratio requirements roof sample sapwood shakes shear shear strength sheet slope of grain spaced span specified splits square inch steel stiffeners stress Structural surface Table temperature tensile tensile strength tension laminations test specimens thickness Type U.B.C. Standard Uniform Building Code values veneer weight welds wide face wire wood failure yield strength Zone