Page 557
... Prestressing Stress - relieved Strand Scope Sec . 26.701 . This part of this standard covers two grades of seven - wire , uncoated , stress - relieved steel strand for use in pretensioned and posttensioned prestressed concrete ...
... Prestressing Stress - relieved Strand Scope Sec . 26.701 . This part of this standard covers two grades of seven - wire , uncoated , stress - relieved steel strand for use in pretensioned and posttensioned prestressed concrete ...
Page 767
... prestress and live load . T1 = Net tension in cable due to dead load , prestress , live load and wind or earthquake . T1 = Net tension in cable during erection of the structure . T. Net tension in cable due to dead load , prestress and ...
... prestress and live load . T1 = Net tension in cable due to dead load , prestress , live load and wind or earthquake . T1 = Net tension in cable during erection of the structure . T. Net tension in cable due to dead load , prestress and ...
Page 1116
... prestressing tendon ( bottom steel ) for prestressed concrete beams is shown in Table No. 43-9 - M for fire- resistance ratings of one hour to four hours . Concrete Columns Sec . 43.909 . ( a ) Minimum Size . Table No. 43-9 - N shows ...
... prestressing tendon ( bottom steel ) for prestressed concrete beams is shown in Table No. 43-9 - M for fire- resistance ratings of one hour to four hours . Concrete Columns Sec . 43.909 . ( a ) Minimum Size . Table No. 43-9 - N shows ...
Other editions - View all
Uniform Building Code Standards International Conference of Building Officials No preview available - 1979 |
Common terms and phrases
½ inch accordance adhesive admixture aggregate allowable load applied average axis beam bending bolt BUILDING CODE STANDARD cement characteristics coating combination compression members compressive strength concrete concrete masonry units conform connector cross section deck determined diameter dimensions Douglas fir E-rated edge end joints equivalent exceed feet fiber flange glue glued holes joists knots laminations lams length less lumber manufactured material maximum measured medium method minimum modulus of elasticity moisture content mortar nominal panel parallel percent permitted perpendicular piece pitch plate plywood portland cement pounds per square pozzolan procedures ratio requirements roof sample sapwood shakes shear shear strength sheet slope of grain spaced span specified splits square inch steel stiffeners stress Structural surface Table temperature tensile tensile strength tension laminations test specimens thickness Type U.B.C. Standard Uniform Building Code values veneer weight welds wide face wire wood failure yield strength Zone