Page 31
... shear walls . ( b ) Definition . BRICK is a solid clay masonry unit . ( c ) Grades . Three grades of brick are covered : Grade SW . Brick intended for use where a high degree of resistance to frost action is desired and the exposure is ...
... shear walls . ( b ) Definition . BRICK is a solid clay masonry unit . ( c ) Grades . Three grades of brick are covered : Grade SW . Brick intended for use where a high degree of resistance to frost action is desired and the exposure is ...
Page 391
... Shear Stresses . Shear stresses shall be calculated by the following formula ... walls , shall be placed in all bays . Spacing shall be as required by the ... shear forces . Part III - Plywood Beams Scope Sec . 25.1813 . This standard ...
... Shear Stresses . Shear stresses shall be calculated by the following formula ... walls , shall be placed in all bays . Spacing shall be as required by the ... shear forces . Part III - Plywood Beams Scope Sec . 25.1813 . This standard ...
Page 705
... shear walls , attachment to an adjacent structure having adequate lateral stability , or by floor slabs or roof decks secured horizontally by walls or bracing systems parallel to the plane of the frame , and in trusses , the effective ...
... shear walls , attachment to an adjacent structure having adequate lateral stability , or by floor slabs or roof decks secured horizontally by walls or bracing systems parallel to the plane of the frame , and in trusses , the effective ...
Other editions - View all
Uniform Building Code Standards International Conference of Building Officials No preview available - 1979 |
Common terms and phrases
½ inch accordance adhesive admixture aggregate allowable load applied average axis beam bending bolt BUILDING CODE STANDARD cement characteristics coating combination compression members compressive strength concrete concrete masonry units conform connector cross section deck determined diameter dimensions Douglas fir E-rated edge end joints equivalent exceed feet fiber flange glue glued holes joists knots laminations lams length less lumber manufactured material maximum measured medium method minimum modulus of elasticity moisture content mortar nominal panel parallel percent permitted perpendicular piece pitch plate plywood portland cement pounds per square pozzolan procedures ratio requirements roof sample sapwood shakes shear shear strength sheet slope of grain spaced span specified splits square inch steel stiffeners stress Structural surface Table temperature tensile tensile strength tension laminations test specimens thickness Type U.B.C. Standard Uniform Building Code values veneer weight welds wide face wire wood failure yield strength Zone