Uniform Building Code Standards |
From inside the book
Results 1-3 of 7
Page 895
... sound pressure levels produced in a room directly below the test floor on which a " standard " tapping machine is operated . Definitions Sec . 35.202 . For the purpose of this standard , the following definitions and symbols apply ...
... sound pressure levels produced in a room directly below the test floor on which a " standard " tapping machine is operated . Definitions Sec . 35.202 . For the purpose of this standard , the following definitions and symbols apply ...
Page 896
... sound pressure level produced in the receiving room . ( c ) Determination of Average Sound Pressure Levels . The space - average sound pressure level shall be determined using an indicating device which reads root mean square values ...
... sound pressure level produced in the receiving room . ( c ) Determination of Average Sound Pressure Levels . The space - average sound pressure level shall be determined using an indicating device which reads root mean square values ...
Page 906
... Noise Level . The background noise levels in the receiving room shall be given in graphic form , in comparison with the actual average sound pressure levels observed during the transmission loss tests on both sides of the test partition ...
... Noise Level . The background noise levels in the receiving room shall be given in graphic form , in comparison with the actual average sound pressure levels observed during the transmission loss tests on both sides of the test partition ...
Other editions - View all
Uniform Building Code Standards International Conference of Building Officials No preview available - 1979 |
Common terms and phrases
½ inch accordance adhesive admixture aggregate allowable load applied average axis beam bending bolt BUILDING CODE STANDARD cement characteristics coating combination compression members compressive strength concrete concrete masonry units conform connector cross section deck determined diameter dimensions Douglas fir E-rated edge end joints equivalent exceed feet fiber flange glue glued holes joists knots laminations lams length less lumber manufactured material maximum measured medium method minimum modulus of elasticity moisture content mortar nominal panel parallel percent permitted perpendicular piece pitch plate plywood portland cement pounds per square pozzolan procedures ratio requirements roof sample sapwood shakes shear shear strength sheet slope of grain spaced span specified splits square inch steel stiffeners stress Structural surface Table temperature tensile tensile strength tension laminations test specimens thickness Type U.B.C. Standard Uniform Building Code values veneer weight welds wide face wire wood failure yield strength Zone