Uniform Building Code Standards |
From inside the book
Results 1-3 of 81
Page 167
... specified in Table No. 25-9 - L or 25-9 - N ( Wet , Dry and / or Wet / Redry ) . Deflection . At least 90 percent of ... Section 25.917 . The tests shall be conducted for each exposure condition specified in Table No. 25-9 - M or 25-9-0 ...
... specified in Table No. 25-9 - L or 25-9 - N ( Wet , Dry and / or Wet / Redry ) . Deflection . At least 90 percent of ... Section 25.917 . The tests shall be conducted for each exposure condition specified in Table No. 25-9 - M or 25-9-0 ...
Page 556
... provided that the smaller wire is not smaller than D - 4 . Tension Tests and Weld Shear Tests Sec . 26.634 . Tests for determination of conformance to the requirements of Section 26.633 may be made on the welded wire fabric after ...
... provided that the smaller wire is not smaller than D - 4 . Tension Tests and Weld Shear Tests Sec . 26.634 . Tests for determination of conformance to the requirements of Section 26.633 may be made on the welded wire fabric after ...
Page 1129
... described in Section 47.204 shall show no less than 75 percent transfer ( by area ) to the back surface of the gypsum wallboard or no less than 75 percent paper failure . ( b ) Wetting Characteristics . The adhesive shall wet the ...
... described in Section 47.204 shall show no less than 75 percent transfer ( by area ) to the back surface of the gypsum wallboard or no less than 75 percent paper failure . ( b ) Wetting Characteristics . The adhesive shall wet the ...
Other editions - View all
Uniform Building Code Standards International Conference of Building Officials No preview available - 1979 |
Common terms and phrases
½ inch accordance adhesive admixture aggregate allowable load applied average axis beam bending bolt BUILDING CODE STANDARD cement characteristics coating combination compression members compressive strength concrete concrete masonry units conform connector cross section deck determined diameter dimensions Douglas fir E-rated edge end joints equivalent exceed feet fiber flange glue glued holes joists knots laminations lams length less lumber manufactured material maximum measured medium method minimum modulus of elasticity moisture content mortar nominal panel parallel percent permitted perpendicular piece pitch plate plywood portland cement pounds per square pozzolan procedures ratio requirements roof sample sapwood shakes shear shear strength sheet slope of grain spaced span specified splits square inch steel stiffeners stress Structural surface Table temperature tensile tensile strength tension laminations test specimens thickness Type U.B.C. Standard Uniform Building Code values veneer weight welds wide face wire wood failure yield strength Zone