Page 49
... surface that has been coated with oil . Place the surface to be capped on this mortar , and firmly press down with a single motion the specimen , so held that its axis is at right angles to the capping surface . After the cap has ...
... surface that has been coated with oil . Place the surface to be capped on this mortar , and firmly press down with a single motion the specimen , so held that its axis is at right angles to the capping surface . After the cap has ...
Page 332
International Conference of Building Officials. = SIDE - GRAIN SURFACE means a surface parallel to the general direction of the wood fibers ( a 0 ° ) , such as the top , bottom and sides of a straight member . SLOPING SURFACE means a ...
International Conference of Building Officials. = SIDE - GRAIN SURFACE means a surface parallel to the general direction of the wood fibers ( a 0 ° ) , such as the top , bottom and sides of a straight member . SLOPING SURFACE means a ...
Page 1214
... surface of sheet glass . OPEN GASEOUS INCLUSIONS . Bubbles at the surface of glass which are open leaving a cavity in the finished surface . PROCESS SURFACE DEFECTS . The surfaces of plate glass have very fine sur- face defects ...
... surface of sheet glass . OPEN GASEOUS INCLUSIONS . Bubbles at the surface of glass which are open leaving a cavity in the finished surface . PROCESS SURFACE DEFECTS . The surfaces of plate glass have very fine sur- face defects ...
Other editions - View all
Uniform Building Code Standards International Conference of Building Officials No preview available - 1979 |
Common terms and phrases
½ inch accordance adhesive admixture aggregate allowable load applied average axis beam bending bolt BUILDING CODE STANDARD cement characteristics coating combination compression members compressive strength concrete concrete masonry units conform connector cross section deck determined diameter dimensions Douglas fir E-rated edge end joints equivalent exceed feet fiber flange glue glued holes joists knots laminations lams length less lumber manufactured material maximum measured medium method minimum modulus of elasticity moisture content mortar nominal panel parallel percent permitted perpendicular piece pitch plate plywood portland cement pounds per square pozzolan procedures ratio requirements roof sample sapwood shakes shear shear strength sheet slope of grain spaced span specified splits square inch steel stiffeners stress Structural surface Table temperature tensile tensile strength tension laminations test specimens thickness Type U.B.C. Standard Uniform Building Code values veneer weight welds wide face wire wood failure yield strength Zone