Page 74
... face on which it is measured ( see Figure No. 25-1-1 ) . A corner knot in a joist containing the pith is measured either by its width on the narrow face between lines parallel to the edge , or by its smallest diameter on the wide face ...
... face on which it is measured ( see Figure No. 25-1-1 ) . A corner knot in a joist containing the pith is measured either by its width on the narrow face between lines parallel to the edge , or by its smallest diameter on the wide face ...
Page 131
International Conference of Building Officials. WIDE FACE ( WIDTH ) 8 " 10 " 12 " 14 " 16 " 18 " and wider KNOT AT CENTER LINE OF WIDE FACES 2 " 22 " 3 " 31⁄4 " 32 " 334 " Knots at the edge of the wide face may increase proportionately ...
International Conference of Building Officials. WIDE FACE ( WIDTH ) 8 " 10 " 12 " 14 " 16 " 18 " and wider KNOT AT CENTER LINE OF WIDE FACES 2 " 22 " 3 " 31⁄4 " 32 " 334 " Knots at the edge of the wide face may increase proportionately ...
Page 151
... WIDE KNOTS 18 " 24 22 ' " 3 " 34 " 31⁄2 " WIDE FACE ( WIDTH ) KNOT AT CENTER LINE OF WIDE FACES 3 " 334 " 42 L T 8 " 10 " 12 " 14 " 16 " 18 " and wider 434 51⁄2 " Knots at the edge of the wide face may increase 151 1985 EDITION 25-8.
... WIDE KNOTS 18 " 24 22 ' " 3 " 34 " 31⁄2 " WIDE FACE ( WIDTH ) KNOT AT CENTER LINE OF WIDE FACES 3 " 334 " 42 L T 8 " 10 " 12 " 14 " 16 " 18 " and wider 434 51⁄2 " Knots at the edge of the wide face may increase 151 1985 EDITION 25-8.
Other editions - View all
Uniform Building Code Standards International Conference of Building Officials No preview available - 1979 |
Common terms and phrases
½ inch accordance adhesive admixture aggregate allowable load applied average axis beam bending bolt BUILDING CODE STANDARD cement characteristics coating combination compression members compressive strength concrete concrete masonry units conform connector cross section deck determined diameter dimensions Douglas fir E-rated edge end joints equivalent exceed feet fiber flange glue glued holes joists knots laminations lams length less lumber manufactured material maximum measured medium method minimum modulus of elasticity moisture content mortar nominal panel parallel percent permitted perpendicular piece pitch plate plywood portland cement pounds per square pozzolan procedures ratio requirements roof sample sapwood shakes shear shear strength sheet slope of grain spaced span specified splits square inch steel stiffeners stress Structural surface Table temperature tensile tensile strength tension laminations test specimens thickness Type U.B.C. Standard Uniform Building Code values veneer weight welds wide face wire wood failure yield strength Zone