Uniform Building Code Standards |
From inside the book
Results 1-3 of 92
Page 343
If the penetration is less than seven diameters , the allowable load shall be
reduced proportionately , but a penetration of less than four diameters shall not
be used . ( b ) Allowable Loads for Lateral Resistance with Wood Screws in Side
Grain .
If the penetration is less than seven diameters , the allowable load shall be
reduced proportionately , but a penetration of less than four diameters shall not
be used . ( b ) Allowable Loads for Lateral Resistance with Wood Screws in Side
Grain .
Page 419
DELAMINATION is separation of the wood surfaces at the bonded joints caused
by a cohesive failure in the adhesive or a failure of the adhesive at the wood
surface . Classification Sec . 25 . 1915 . The adhesive shall be classified by the ...
DELAMINATION is separation of the wood surfaces at the bonded joints caused
by a cohesive failure in the adhesive or a failure of the adhesive at the wood
surface . Classification Sec . 25 . 1915 . The adhesive shall be classified by the ...
Page 423
If the deformation requirements of Subsection ( c ) are not satisfied but the wood
failure is 95 percent or more , the adhesive may be retested . Physical
Requirements Sec . 25 . 1925 . ( a ) General . The adhesive manufacturer shall
furnish ...
If the deformation requirements of Subsection ( c ) are not satisfied but the wood
failure is 95 percent or more , the adhesive may be retested . Physical
Requirements Sec . 25 . 1925 . ( a ) General . The adhesive manufacturer shall
furnish ...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Other editions - View all
Uniform Building Code Standards International Conference of Building Officials No preview available - 1979 |
Common terms and phrases
accordance aggregate allowable applied assembly average beam bending bolt cement characteristics checks coating combination compression compression stress concrete conform connections construction containing Continued covers cross depth determined diameter dimensions direction distance door edge effective element end joints equal exceed face feet Figure fire flange foot grade grain greater Group holes inches joists knots laminations least length less light limited load located lumber manufacturer material maximum measured medium method moisture nominal panel parallel percent period permitted piece pine pitch placed plate plywood pounds pressure procedures requirements sample Section shear sheet shown side slope sound spaced specified square steel stiffeners strength stress structural surface Table temperature tension test specimens thickness Type U.B.C. Standard Uniform Building Code unit values weight welds wide width wire wood Zone