Uniform Building Code Standards |
From inside the book
Results 1-3 of 9
Page xvii
... Shingles Made from Asphalt Organic Felt . Standard Specification 55 - B , October 5 , 1983 , of the Underwriters ... Wood Shakes . Part I — Wood Shakes ( nonpreservative treated ) . Grading and Packing Rules for Red Cedar Shakes of the ...
... Shingles Made from Asphalt Organic Felt . Standard Specification 55 - B , October 5 , 1983 , of the Underwriters ... Wood Shakes . Part I — Wood Shakes ( nonpreservative treated ) . Grading and Packing Rules for Red Cedar Shakes of the ...
Page 856
... wood shingles and shakes are to be classified as Class A or Class B. A 43 - foot - long test deck is to be mounted in the same manner , and a similar lum- inous gas flame is to be used as described in Section 32.702 ( b ) , second ...
... wood shingles and shakes are to be classified as Class A or Class B. A 43 - foot - long test deck is to be mounted in the same manner , and a similar lum- inous gas flame is to be used as described in Section 32.702 ( b ) , second ...
Page 869
International Conference of Building Officials. UNIFORM BUILDING CODE STANDARD NO . 32-11 WOOD SHINGLES Based on the Standards of the Red Cedar Shingle & Handsplit Shake Bureau and Material Standard of the International Conference of ...
International Conference of Building Officials. UNIFORM BUILDING CODE STANDARD NO . 32-11 WOOD SHINGLES Based on the Standards of the Red Cedar Shingle & Handsplit Shake Bureau and Material Standard of the International Conference of ...
Other editions - View all
Uniform Building Code Standards International Conference of Building Officials No preview available - 1979 |
Common terms and phrases
½ inch accordance adhesive admixture aggregate allowable load applied average axis beam bending bolt BUILDING CODE STANDARD cement characteristics coating combination compression members compressive strength concrete concrete masonry units conform connector cross section deck determined diameter dimensions Douglas fir E-rated edge end joints equivalent exceed feet fiber flange glue glued holes joists knots laminations lams length less lumber manufactured material maximum measured medium method minimum modulus of elasticity moisture content mortar nominal panel parallel percent permitted perpendicular piece pitch plate plywood portland cement pounds per square pozzolan procedures ratio requirements roof sample sapwood shakes shear shear strength sheet slope of grain spaced span specified splits square inch steel stiffeners stress Structural surface Table temperature tensile tensile strength tension laminations test specimens thickness Type U.B.C. Standard Uniform Building Code values veneer weight welds wide face wire wood failure yield strength Zone