Uniform Building CodeInternational Conference of Building Officials, 1991 - Building laws |
From inside the book
Results 1-3 of 73
Page 110
... Standard No. 17-5 , Room Fire Test Standard for Interior Foam Plastic Systems , Standard of the International Conference of Building Officials E.U.B.C. Standard No. 17-6 , Method of Test for the Evaluation of Flammability ...
... Standard No. 17-5 , Room Fire Test Standard for Interior Foam Plastic Systems , Standard of the International Conference of Building Officials E.U.B.C. Standard No. 17-6 , Method of Test for the Evaluation of Flammability ...
Page 247
... standard " are also listed in Chapter 60 , Part II , and are part of this code . The other standards listed below ... Standard No. 25-1 , Classification , Definition and Methods of Grad- ing for All Species of Lumber B. Standard Grading ...
... standard " are also listed in Chapter 60 , Part II , and are part of this code . The other standards listed below ... Standard No. 25-1 , Classification , Definition and Methods of Grad- ing for All Species of Lumber B. Standard Grading ...
Page 695
... standards listed below labeled a “ U.B.C. standard ” are also listed in Chapter 60 , Part II , and are part of this code . The other standards listed below are guideline standards and as such are not adopted as part of this code ( see ...
... standards listed below labeled a “ U.B.C. standard ” are also listed in Chapter 60 , Part II , and are part of this code . The other standards listed below are guideline standards and as such are not adopted as part of this code ( see ...
Contents
Permits and Inspections | 9 |
Part IIDefinitions and Abbreviations | 21 |
Part IIIRequirements Based on Occupancy | 35 |
Copyright | |
152 other sections not shown
Other editions - View all
Common terms and phrases
accordance with Section anchored applied approved assembly ASTM bars beam bending bolts building official cement Chapter column comply compression compression members compressive strength concrete conform corridor dead load Decking diaphragms Division doors exceed exit exterior walls factor fire fire-resistive rating flexural floor forces framing gauge grade grout gypsum height horizontal installed joints joists lath less live load located masonry materials maximum minimum modulus of elasticity nails Nonbuilding structures noncombustible occupant load one-hour fire-resistive openings panel particleboard percent perpendicular plaster plywood portland cement pounds per square prestressed protected requirements of Section resist roof rooms Seismic Zones Select Structural shear reinforcement shear strength shear walls sheathing slab smoke detector spaced span specified in Section splices square feet square inch stairway steel story studs surface Table tension thickness tion Type U.B.C. Standard values vertical wallboard welded width wire wood WWPA yield strength