Uniform Building CodeInternational Conference of Building Officials, 1991 - Building laws |
From inside the book
Results 1-3 of 69
Page 608
... Roof Covering . A Class A roof covering shall be one of the following roofings : 1. Any Class A roofing assembly . 2. Asbestos - cement shingles or sheets . 3. Exposed concrete slab roof . 4. Sheet ferrous or copper roof covering . 5 ...
... Roof Covering . A Class A roof covering shall be one of the following roofings : 1. Any Class A roofing assembly . 2. Asbestos - cement shingles or sheets . 3. Exposed concrete slab roof . 4. Sheet ferrous or copper roof covering . 5 ...
Page 663
International Conference of Building Officials. Chapter 36 PENTHOUSES AND ROOF STRUCTURES Penthouses and Roof Structures Sec . 3601. ( a ) Height . No penthouse or other projection above the roof in struc- tures of other than Type I ...
International Conference of Building Officials. Chapter 36 PENTHOUSES AND ROOF STRUCTURES Penthouses and Roof Structures Sec . 3601. ( a ) Height . No penthouse or other projection above the roof in struc- tures of other than Type I ...
Page 971
... roof structure for compliance with Section 3207 shall be made and corrective measures , such as relocation of roof drains or scuppers , resloping of the roof or structural changes , shall be made . An inspection report covering the ...
... roof structure for compliance with Section 3207 shall be made and corrective measures , such as relocation of roof drains or scuppers , resloping of the roof or structural changes , shall be made . An inspection report covering the ...
Contents
Permits and Inspections | 9 |
Part IIDefinitions and Abbreviations | 21 |
Part IIIRequirements Based on Occupancy | 35 |
Copyright | |
152 other sections not shown
Other editions - View all
Common terms and phrases
accordance with Section anchored applied approved assembly ASTM bars beam bending bolts building official cement Chapter column comply compression compression members compressive strength concrete conform corridor dead load Decking diaphragms Division doors exceed exit exterior walls factor fire fire-resistive rating flexural floor forces framing gauge grade grout gypsum height horizontal installed joints joists lath less live load located masonry materials maximum minimum modulus of elasticity nails Nonbuilding structures noncombustible occupant load one-hour fire-resistive openings panel particleboard percent perpendicular plaster plywood portland cement pounds per square prestressed protected requirements of Section resist roof rooms Seismic Zones Select Structural shear reinforcement shear strength shear walls sheathing slab smoke detector spaced span specified in Section splices square feet square inch stairway steel story studs surface Table tension thickness tion Type U.B.C. Standard values vertical wallboard welded width wire wood WWPA yield strength