Uniform Building CodeInternational Conference of Building Officials, 1991 - Building laws |
From inside the book
Results 1-3 of 75
Page 104
... rooms and habitable rooms within a dwelling unit or congre- gate residence shall be provided with natural light by means of exterior glazed openings with an area not less than one tenth of the floor area of such rooms with a minimum of ...
... rooms and habitable rooms within a dwelling unit or congre- gate residence shall be provided with natural light by means of exterior glazed openings with an area not less than one tenth of the floor area of such rooms with a minimum of ...
Page 654
... rooms . 4. Fixed fully tempered or laminated glass in wood or metal frames may be used in corridor walls , provided the glazed area does not exceed 25 percent of the area of the corridor wall of the room . 5. The total area of glass in ...
... rooms . 4. Fixed fully tempered or laminated glass in wood or metal frames may be used in corridor walls , provided the glazed area does not exceed 25 percent of the area of the corridor wall of the room . 5. The total area of glass in ...
Page 687
... rooms shall comply with the Fire Code . ( b ) Projection Room Required . Every motion picture machine projecting film as mentioned within the scope of this chapter shall be enclosed in a projection room . Appurtenant electrical ...
... rooms shall comply with the Fire Code . ( b ) Projection Room Required . Every motion picture machine projecting film as mentioned within the scope of this chapter shall be enclosed in a projection room . Appurtenant electrical ...
Contents
Permits and Inspections | 9 |
Part IIDefinitions and Abbreviations | 21 |
Part IIIRequirements Based on Occupancy | 35 |
Copyright | |
152 other sections not shown
Other editions - View all
Common terms and phrases
accordance with Section anchored applied approved assembly ASTM bars beam bending bolts building official cement Chapter column comply compression compression members compressive strength concrete conform corridor dead load Decking diaphragms Division doors exceed exit exterior walls factor fire fire-resistive rating flexural floor forces framing gauge grade grout gypsum height horizontal installed joints joists lath less live load located masonry materials maximum minimum modulus of elasticity nails Nonbuilding structures noncombustible occupant load one-hour fire-resistive openings panel particleboard percent perpendicular plaster plywood portland cement pounds per square prestressed protected requirements of Section resist roof rooms Seismic Zones Select Structural shear reinforcement shear strength shear walls sheathing slab smoke detector spaced span specified in Section splices square feet square inch stairway steel story studs surface Table tension thickness tion Type U.B.C. Standard values vertical wallboard welded width wire wood WWPA yield strength