Uniform Building Code, Volume 7International Conference of Building Officials, 1970 - Building laws |
From inside the book
Results 1-3 of 17
Page 7
... Group H Occupancies SEC . 1301 . Group H Occupancies Defined 55 1302 . 1303 . Construction , Height , and Allowable Area Location on Property 55 55 1304 . Exit Facilities 55 1305 . Light , Ventilation , and Sanitation 56 1306. Yards and ...
... Group H Occupancies SEC . 1301 . Group H Occupancies Defined 55 1302 . 1303 . Construction , Height , and Allowable Area Location on Property 55 55 1304 . Exit Facilities 55 1305 . Light , Ventilation , and Sanitation 56 1306. Yards and ...
Page 49
... Group F Occupancies shall be : Division 1. Gasoline service stations , storage garages where no repair work is done ... H Occupancy may be classed as a separate and distinct building for the purpose of area limitation , limitation of number ...
... Group F Occupancies shall be : Division 1. Gasoline service stations , storage garages where no repair work is done ... H Occupancy may be classed as a separate and distinct building for the purpose of area limitation , limitation of number ...
Page 55
... Group H Occupancies shall be : Hotels and apartment houses . Group H Occupancies Convents and monasteries ( each accommodating more than 10 Defined persons ) . For occupancy separations see Table No. 5 - B . For occupant load see ...
... Group H Occupancies shall be : Hotels and apartment houses . Group H Occupancies Convents and monasteries ( each accommodating more than 10 Defined persons ) . For occupancy separations see Table No. 5 - B . For occupant load see ...
Contents
Part 1Administrative | 11 |
303 | 17 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
1 other sections not shown
Other editions - View all
Common terms and phrases
12 inches 20 feet aisle Allowable Area applied approved automatic fire-extinguishing systems Building Official building or structure cavity walls Ceiling Ceiling Ceiling cent combustible conform corridor Division exceed exit doors exterior exit exterior walls feet 1 hour feet Not permitted feet Protected less fire assembly Fire Zone fire-resistive rating fireplace Firestopping flammable liquids floor area garages gauge grade Group D Occupancies Group F grout Gypsum Lath gypsum wallboard H Occupancies horizontal hour less inches installed joists less than 20 Location on Property locking device lumber Masonry chimneys materials maximum metal lath minimum nail noncombustible occupant load one-hour fire-resistive construction partitions permitted less portland cement plaster pounds per square rafters ramp seats Shaft Enclosures sheathing shingles soffits space specified in Chapter specified in Section square feet Stairs stairway stories in height studs surfaces Table types of construction U.B.C. Standard Uniform Building Code veneer ventilation vertical water closet wire fabric lath Wood shingles