Uniform Building Code, Volume 7International Conference of Building Officials, 1970 - Building laws |
From inside the book
Results 1-3 of 72
Page 71
... Table No. 25 - F of the Uniform Building Code . Lumber set forth in Group IV of Table No. 25 - F may be used only under conditions specifically approved by the Building Official . ( b ) Nailing . Nailing of members shall be as set forth ...
... Table No. 25 - F of the Uniform Building Code . Lumber set forth in Group IV of Table No. 25 - F may be used only under conditions specifically approved by the Building Official . ( b ) Nailing . Nailing of members shall be as set forth ...
Page 119
... Table No. 24 - I , blocking having the same cross - sectional dimensions as the studs shall be provided at all joints that are perpendicular to the studs . The size and spacing of nails shall be as set forth in Table No. 24 - I . Nails ...
... Table No. 24 - I , blocking having the same cross - sectional dimensions as the studs shall be provided at all joints that are perpendicular to the studs . The size and spacing of nails shall be as set forth in Table No. 24 - I . Nails ...
Page 129
... Table No. 24 - G . 7 100 Unblocked 4 125 1/2 " 5d cooler nails. THICKNESS OF GYPSUM WALLBOARD FRAMING MEMBERS MAXIMUM ... Table No. 24 - I . 2Nails for wood framing shall be long enough to penetrate into wood members not less than 4 inch ...
... Table No. 24 - G . 7 100 Unblocked 4 125 1/2 " 5d cooler nails. THICKNESS OF GYPSUM WALLBOARD FRAMING MEMBERS MAXIMUM ... Table No. 24 - I . 2Nails for wood framing shall be long enough to penetrate into wood members not less than 4 inch ...
Contents
Part 1Administrative | 11 |
303 | 17 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
1 other sections not shown
Other editions - View all
Common terms and phrases
12 inches 20 feet aisle Allowable Area applied approved automatic fire-extinguishing systems Building Official building or structure cavity walls Ceiling Ceiling Ceiling cent combustible conform corridor Division exceed exit doors exterior exit exterior walls feet 1 hour feet Not permitted feet Protected less fire assembly Fire Zone fire-resistive rating fireplace Firestopping flammable liquids floor area garages gauge grade Group D Occupancies Group F grout Gypsum Lath gypsum wallboard H Occupancies horizontal hour less inches installed joists less than 20 Location on Property locking device lumber Masonry chimneys materials maximum metal lath minimum nail noncombustible occupant load one-hour fire-resistive construction partitions permitted less portland cement plaster pounds per square rafters ramp seats Shaft Enclosures sheathing shingles soffits space specified in Chapter specified in Section square feet Stairs stairway stories in height studs surfaces Table types of construction U.B.C. Standard Uniform Building Code veneer ventilation vertical water closet wire fabric lath Wood shingles