Page 86
... Shingles or Shakes . Wood shingles or shakes and asbestos cement shingles may be used for exterior wall covering provided the frame of the structure is covered with building paper as specified in Section 1707 ( a ) . All shingles or ...
... Shingles or Shakes . Wood shingles or shakes and asbestos cement shingles may be used for exterior wall covering provided the frame of the structure is covered with building paper as specified in Section 1707 ( a ) . All shingles or ...
Page 95
... Wood Shingles . Shingles may be applied to roofs with solid or spaced sheathing . The spaced sheathing shall be spaced not to exceed 4 inches clear nor more than the width of the sheathing board . Spaced sheathing shall be not less than ...
... Wood Shingles . Shingles may be applied to roofs with solid or spaced sheathing . The spaced sheathing shall be spaced not to exceed 4 inches clear nor more than the width of the sheathing board . Spaced sheathing shall be not less than ...
Page 104
... WOOD SHINGLES PITCH OF ROOF SHINGLE LENGTH RISE RUN 16 - INCH 18 - INCH 24 - INCH 3 " to less than 4 " 12 " 34 " 41/4 " 5 % " 4 " or more 12 " 5 " 52 " 72 ' TAPERED WOOD SHAKES EXPOSURE TO WEATHER LENGTH OF SHAKE 72 " 10 " 18 " 24 " 13 ...
... WOOD SHINGLES PITCH OF ROOF SHINGLE LENGTH RISE RUN 16 - INCH 18 - INCH 24 - INCH 3 " to less than 4 " 12 " 34 " 41/4 " 5 % " 4 " or more 12 " 5 " 52 " 72 ' TAPERED WOOD SHAKES EXPOSURE TO WEATHER LENGTH OF SHAKE 72 " 10 " 18 " 24 " 13 ...
Contents
Part 1Administrative | 11 |
303 | 17 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
1 other sections not shown
Other editions - View all
Common terms and phrases
12 inches 20 feet aisle Allowable Area applied approved automatic fire-extinguishing systems Building Official building or structure cavity walls Ceiling Ceiling Ceiling cent combustible conform corridor Division exceed exit doors exterior exit exterior walls feet 1 hour feet Not permitted feet Protected less fire assembly Fire Zone fire-resistive rating fireplace Firestopping flammable liquids floor area garages gauge grade Group D Occupancies Group F grout Gypsum Lath gypsum wallboard H Occupancies horizontal hour less inches installed joists less than 20 Location on Property locking device lumber Masonry chimneys materials maximum metal lath minimum nail noncombustible occupant load one-hour fire-resistive construction partitions permitted less portland cement plaster pounds per square rafters ramp seats Shaft Enclosures sheathing shingles soffits space specified in Chapter specified in Section square feet Stairs stairway stories in height studs surfaces Table types of construction U.B.C. Standard Uniform Building Code veneer ventilation vertical water closet wire fabric lath Wood shingles