Uniform Building Code, Volume 7International Conference of Building Officials, 1970 - Building laws |
From inside the book
Results 1-3 of 18
Page 11
... construction , alteration , moving , demolition , repair , and use of any building or structure within the city , except work located primarily in a public way , public utility towers and poles , mechanical equipment not specifically ...
... construction , alteration , moving , demolition , repair , and use of any building or structure within the city , except work located primarily in a public way , public utility towers and poles , mechanical equipment not specifically ...
Page 12
... building or struc- ture and complying with the requirements for new buildings or structures may be made to such building or structure within any 12 - month period without making the entire building or structure comply . The new construction ...
... building or struc- ture and complying with the requirements for new buildings or structures may be made to such building or structure within any 12 - month period without making the entire building or structure comply . The new construction ...
Page 19
... building or structure beyond the point indicated in each succes- ( Continued ) sive inspection without first obtaining the written approval of the Building Official . Such written approval shall be given only after an inspection shall ...
... building or structure beyond the point indicated in each succes- ( Continued ) sive inspection without first obtaining the written approval of the Building Official . Such written approval shall be given only after an inspection shall ...
Contents
Part 1Administrative | 11 |
303 | 17 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
1 other sections not shown
Other editions - View all
Common terms and phrases
12 inches 20 feet aisle Allowable Area applied approved automatic fire-extinguishing systems Building Official building or structure cavity walls Ceiling Ceiling Ceiling cent combustible conform corridor Division exceed exit doors exterior exit exterior walls feet 1 hour feet Not permitted feet Protected less fire assembly Fire Zone fire-resistive rating fireplace Firestopping flammable liquids floor area garages gauge grade Group D Occupancies Group F grout Gypsum Lath gypsum wallboard H Occupancies horizontal hour less inches installed joists less than 20 Location on Property locking device lumber Masonry chimneys materials maximum metal lath minimum nail noncombustible occupant load one-hour fire-resistive construction partitions permitted less portland cement plaster pounds per square rafters ramp seats Shaft Enclosures sheathing shingles soffits space specified in Chapter specified in Section square feet Stairs stairway stories in height studs surfaces Table types of construction U.B.C. Standard Uniform Building Code veneer ventilation vertical water closet wire fabric lath Wood shingles