Uniform Building Code, Volume 7International Conference of Building Officials, 1970 - Building laws |
From inside the book
Results 1-3 of 16
Page 34
... combustible , storage and sales rooms for combustible goods , paint stores without bulk handling ..... 1102 2 1 hour Not permitted less than 5 feet Protected less than 10 feet Buildings or portions of buildings having rooms used for ...
... combustible , storage and sales rooms for combustible goods , paint stores without bulk handling ..... 1102 2 1 hour Not permitted less than 5 feet Protected less than 10 feet Buildings or portions of buildings having rooms used for ...
Page 35
... Combustible construction not permitted Noncombustible construction not regulated Combustible construction to be 1 - hour fire - resistive ( In Square Feet ) TYPES OF CONSTRUCTION OCCUPANCY |||. 35 1970 EDITION TABLE NO . 5 - A ( Continued )
... Combustible construction not permitted Noncombustible construction not regulated Combustible construction to be 1 - hour fire - resistive ( In Square Feet ) TYPES OF CONSTRUCTION OCCUPANCY |||. 35 1970 EDITION TABLE NO . 5 - A ( Continued )
Page 69
... combustible materials . 3. Walls where unprotected openings are permitted . 4. Walls on buildings having not more than 1000 square feet of floor area . ( b ) Construction . Parapets shall have the same degree of fire resistance required ...
... combustible materials . 3. Walls where unprotected openings are permitted . 4. Walls on buildings having not more than 1000 square feet of floor area . ( b ) Construction . Parapets shall have the same degree of fire resistance required ...
Contents
Part 1Administrative | 11 |
303 | 17 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
1 other sections not shown
Other editions - View all
Common terms and phrases
12 inches 20 feet aisle Allowable Area applied approved automatic fire-extinguishing systems Building Official building or structure cavity walls Ceiling Ceiling Ceiling cent combustible conform corridor Division exceed exit doors exterior exit exterior walls feet 1 hour feet Not permitted feet Protected less fire assembly Fire Zone fire-resistive rating fireplace Firestopping flammable liquids floor area garages gauge grade Group D Occupancies Group F grout Gypsum Lath gypsum wallboard H Occupancies horizontal hour less inches installed joists less than 20 Location on Property locking device lumber Masonry chimneys materials maximum metal lath minimum nail noncombustible occupant load one-hour fire-resistive construction partitions permitted less portland cement plaster pounds per square rafters ramp seats Shaft Enclosures sheathing shingles soffits space specified in Chapter specified in Section square feet Stairs stairway stories in height studs surfaces Table types of construction U.B.C. Standard Uniform Building Code veneer ventilation vertical water closet wire fabric lath Wood shingles