... Framing shall be effectively and thoroughly braced at each end , or as near ( Continued ) thereto as possible , and at least every 25 feet of length by one of the following methods : 1. Nominal 1 - inch by 4 - inch continuous diagonal ...
... Framing shall be effectively and thoroughly braced at each end , or as near ( Continued ) thereto as possible , and at least every 25 feet of length by one of the following methods : 1. Nominal 1 - inch by 4 - inch continuous diagonal ...
Page 93
... Framing . Rafters shall be framed directly opposite each other at the ridge . There shall be a ridge board at least 1 - inch nominal thickness at all ridges and not less in depth than the cut end of the rafter . At all valleys and hips ...
... Framing . Rafters shall be framed directly opposite each other at the ridge . There shall be a ridge board at least 1 - inch nominal thickness at all ridges and not less in depth than the cut end of the rafter . At all valleys and hips ...
Page 128
... FRAMING MEMBERS Horizontal Either Direction 16 7 12 1/2 Horizontal Perpendicular 24 7 12 Vertical Either Direction ... FRAMING MAXIMUM SPACING OF FRAMING MEMBERS ' MAXIMUM SPACING OF FASTENERS ( Center to Center ) NAILS TO WOOD ( In ...
... FRAMING MEMBERS Horizontal Either Direction 16 7 12 1/2 Horizontal Perpendicular 24 7 12 Vertical Either Direction ... FRAMING MAXIMUM SPACING OF FRAMING MEMBERS ' MAXIMUM SPACING OF FASTENERS ( Center to Center ) NAILS TO WOOD ( In ...
Contents
Part 1Administrative | 11 |
303 | 17 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
1 other sections not shown
Other editions - View all
Common terms and phrases
12 inches 20 feet aisle Allowable Area applied approved automatic fire-extinguishing systems Building Official building or structure cavity walls Ceiling Ceiling Ceiling cent combustible conform corridor Division exceed exit doors exterior exit exterior walls feet 1 hour feet Not permitted feet Protected less fire assembly Fire Zone fire-resistive rating fireplace Firestopping flammable liquids floor area garages gauge grade Group D Occupancies Group F grout Gypsum Lath gypsum wallboard H Occupancies horizontal hour less inches installed joists less than 20 Location on Property locking device lumber Masonry chimneys materials maximum metal lath minimum nail noncombustible occupant load one-hour fire-resistive construction partitions permitted less portland cement plaster pounds per square rafters ramp seats Shaft Enclosures sheathing shingles soffits space specified in Chapter specified in Section square feet Stairs stairway stories in height studs surfaces Table types of construction U.B.C. Standard Uniform Building Code veneer ventilation vertical water closet wire fabric lath Wood shingles