Uniform Building Code, Volume 7International Conference of Building Officials, 1970 - Building laws |
From inside the book
Results 1-3 of 7
Page 8
... Concrete 1803 . Reinforcing Steel 1804 . Mortar 1805 . Masonry Units 71 72 72 72 72 22222 CHAPTER 19 . Foundations SEC . 1901 . General Requirements 1902 . Footings 1903. Preparation of Building Site 1904 . Protection Against Decay and ...
... Concrete 1803 . Reinforcing Steel 1804 . Mortar 1805 . Masonry Units 71 72 72 72 72 22222 CHAPTER 19 . Foundations SEC . 1901 . General Requirements 1902 . Footings 1903. Preparation of Building Site 1904 . Protection Against Decay and ...
Page 107
... reinforced concrete , not less than 4 inches thick with a chimney lining as specified in Subsection ( e ) of this Section . If the grate area of such an incinerator exceeds 9 square feet , walls shall be not less than 4 inches thick and ...
... reinforced concrete , not less than 4 inches thick with a chimney lining as specified in Subsection ( e ) of this Section . If the grate area of such an incinerator exceeds 9 square feet , walls shall be not less than 4 inches thick and ...
Page 110
... concrete , stone or other approved noncombustible hearth slab at least 12 ... reinforced to carry its own weight and all imposed loads . Combustible forms ... concrete fireplaces shall be not less than 12 inches thick , ex- tend not less ...
... concrete , stone or other approved noncombustible hearth slab at least 12 ... reinforced to carry its own weight and all imposed loads . Combustible forms ... concrete fireplaces shall be not less than 12 inches thick , ex- tend not less ...
Contents
Part 1Administrative | 11 |
303 | 17 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
1 other sections not shown
Other editions - View all
Common terms and phrases
12 inches 20 feet aisle Allowable Area applied approved automatic fire-extinguishing systems Building Official building or structure cavity walls Ceiling Ceiling Ceiling cent combustible conform corridor Division exceed exit doors exterior exit exterior walls feet 1 hour feet Not permitted feet Protected less fire assembly Fire Zone fire-resistive rating fireplace Firestopping flammable liquids floor area garages gauge grade Group D Occupancies Group F grout Gypsum Lath gypsum wallboard H Occupancies horizontal hour less inches installed joists less than 20 Location on Property locking device lumber Masonry chimneys materials maximum metal lath minimum nail noncombustible occupant load one-hour fire-resistive construction partitions permitted less portland cement plaster pounds per square rafters ramp seats Shaft Enclosures sheathing shingles soffits space specified in Chapter specified in Section square feet Stairs stairway stories in height studs surfaces Table types of construction U.B.C. Standard Uniform Building Code veneer ventilation vertical water closet wire fabric lath Wood shingles