Uniform Building Code, Volume 7International Conference of Building Officials, 1970 - Building laws |
From inside the book
Results 1-3 of 4
Page 94
... slab roof . 8. Metal roof covering . 9. Slate shingles . 10. Clay or concrete roof tile . 1See U.B.C. Standard No. 32-5 for mineral roofing aggregate weighing less than 60 pounds per cubic foot . 2Shall have a minimum underlay of two ...
... slab roof . 8. Metal roof covering . 9. Slate shingles . 10. Clay or concrete roof tile . 1See U.B.C. Standard No. 32-5 for mineral roofing aggregate weighing less than 60 pounds per cubic foot . 2Shall have a minimum underlay of two ...
Page 110
... slab at least 12 inches wider on each side than the fireplace opening and projecting at least 18 inches therefrom . This slab shall be not less than 4 inches thick and shall be supported by noncombustible mate- rials or reinforced to ...
... slab at least 12 inches wider on each side than the fireplace opening and projecting at least 18 inches therefrom . This slab shall be not less than 4 inches thick and shall be supported by noncombustible mate- rials or reinforced to ...
Page 116
... slab system , exterior plaster shall be applied in such a manner as to cover , but not extend below , lath and paper . See Section 2406 ( e ) for the application of paper and lath , and flash- ing or drip screeds . Only approved ...
... slab system , exterior plaster shall be applied in such a manner as to cover , but not extend below , lath and paper . See Section 2406 ( e ) for the application of paper and lath , and flash- ing or drip screeds . Only approved ...
Contents
Part 1Administrative | 11 |
303 | 17 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
1 other sections not shown
Other editions - View all
Common terms and phrases
12 inches 20 feet aisle Allowable Area applied approved automatic fire-extinguishing systems Building Official building or structure cavity walls Ceiling Ceiling Ceiling cent combustible conform corridor Division exceed exit doors exterior exit exterior walls feet 1 hour feet Not permitted feet Protected less fire assembly Fire Zone fire-resistive rating fireplace Firestopping flammable liquids floor area garages gauge grade Group D Occupancies Group F grout Gypsum Lath gypsum wallboard H Occupancies horizontal hour less inches installed joists less than 20 Location on Property locking device lumber Masonry chimneys materials maximum metal lath minimum nail noncombustible occupant load one-hour fire-resistive construction partitions permitted less portland cement plaster pounds per square rafters ramp seats Shaft Enclosures sheathing shingles soffits space specified in Chapter specified in Section square feet Stairs stairway stories in height studs surfaces Table types of construction U.B.C. Standard Uniform Building Code veneer ventilation vertical water closet wire fabric lath Wood shingles