Uniform Building Code, Volume 7International Conference of Building Officials, 1970 - Building laws |
From inside the book
Results 1-3 of 26
Page 58
... unit shall conform to the requirements of the Code except as herein provided : 1. The unit shall have a living room of not less than 220 square feet of superficial floor area . An additional 100 square feet of super- ficial floor area ...
... unit shall conform to the requirements of the Code except as herein provided : 1. The unit shall have a living room of not less than 220 square feet of superficial floor area . An additional 100 square feet of super- ficial floor area ...
Page 80
... units , laid contigu- ously in mortar . All units shall be laid with full shoved mortar joints , and all head , bed ... Unit ties shall be of sufficient length to engage all wythes , with ends embedded not less than 1 inch in mortar ...
... units , laid contigu- ously in mortar . All units shall be laid with full shoved mortar joints , and all head , bed ... Unit ties shall be of sufficient length to engage all wythes , with ends embedded not less than 1 inch in mortar ...
Page 82
... unit masonry is that type of construction made with hollow masonry units in which the units are all laid and set in mortar . All units shall be laid with full face shell mortar beds . All head and end joints shall be filled solidly with ...
... unit masonry is that type of construction made with hollow masonry units in which the units are all laid and set in mortar . All units shall be laid with full face shell mortar beds . All head and end joints shall be filled solidly with ...
Contents
Part 1Administrative | 11 |
303 | 17 |
Part IIIRequirements Based on Occupancy | 27 |
Copyright | |
1 other sections not shown
Other editions - View all
Common terms and phrases
12 inches 20 feet aisle Allowable Area applied approved automatic fire-extinguishing systems Building Official building or structure cavity walls Ceiling Ceiling Ceiling cent combustible conform corridor Division exceed exit doors exterior exit exterior walls feet 1 hour feet Not permitted feet Protected less fire assembly Fire Zone fire-resistive rating fireplace Firestopping flammable liquids floor area garages gauge grade Group D Occupancies Group F grout Gypsum Lath gypsum wallboard H Occupancies horizontal hour less inches installed joists less than 20 Location on Property locking device lumber Masonry chimneys materials maximum metal lath minimum nail noncombustible occupant load one-hour fire-resistive construction partitions permitted less portland cement plaster pounds per square rafters ramp seats Shaft Enclosures sheathing shingles soffits space specified in Chapter specified in Section square feet Stairs stairway stories in height studs surfaces Table types of construction U.B.C. Standard Uniform Building Code veneer ventilation vertical water closet wire fabric lath Wood shingles