... glue lines 2 inches wide or less , two lines for glue lines more than 2 inches wide and up to 4 inches wide , three lines for glue lines up to 10 inches wide and four lines for 12 - inch - wide glue lines . ( If shorter nail lengths are ...
... glue lines 2 inches wide or less , two lines for glue lines more than 2 inches wide and up to 4 inches wide , three lines for glue lines up to 10 inches wide and four lines for 12 - inch - wide glue lines . ( If shorter nail lengths are ...
Page 492
... glue line ( s ) and tested . ( d ) Adhesives . Adhesive batch or lot tests prior to shipment require 10 specimens ... glue - line block shear specimens may be cut in lieu of stair - step group specimens . 2. For block shear samples , the ...
... glue line ( s ) and tested . ( d ) Adhesives . Adhesive batch or lot tests prior to shipment require 10 specimens ... glue - line block shear specimens may be cut in lieu of stair - step group specimens . 2. For block shear samples , the ...
Page 494
... glue line tested . In reporting results of the shear test , the glue or wood failure revealed on the sheared surfaces of the specimen shall be estimated by a skilled technician . The following steps shall be used for estimating the ...
... glue line tested . In reporting results of the shear test , the glue or wood failure revealed on the sheared surfaces of the specimen shall be estimated by a skilled technician . The following steps shall be used for estimating the ...
Contents
CHAPTER | 7 |
Standard and Subject 1256 October 1979 of the Underwriters Laboratories | 14 |
CHAPTER | 26 |
Copyright | |
11 other sections not shown
Other editions - View all
Common terms and phrases
accordance adhesive allowable load apply average beams bending members Black knots bolt bonding BUILDING CODE STANDARD butt joints combinations compression compression members connector core cross section design value determined diameter dimensions Douglas fir E-rated eastern white pine edge end joints exceed FACE WIDTH feet fiber flange glue lines glued hem-fir holes inch wide Inner knots lag screw laminating grade lams length less limiting provisions localized cross grain lumber manufactured masonry material maximum measured medium grain minimum modulus of elasticity moisture content nails nominal outer tension panel parallel percent permitted perpendicular plies plywood pounds per square procedures requirements sample sapwood scarf joints seasoning checks shake shear shear strength slope of grain southern pine spaced specified splits square inch strength stress structural surface Table temperature tension laminations Tension Zone test specimens thermocouples timber U.B.C. Standard Uniform Building Code veneer visually graded wane wide face wood failure