... holes for anchor bolts may be oversized as follows : BOLT SIZE 3/4 " 7/8 " HOLE SIZE 11/16 " 13/16 " 1 " ≤2 " > 2 ... Holes for Rivets and Bolts . Holes for rivets or bolts shall be 1/16 inch larger than their nominal diameter except ...
... holes for anchor bolts may be oversized as follows : BOLT SIZE 3/4 " 7/8 " HOLE SIZE 11/16 " 13/16 " 1 " ≤2 " > 2 ... Holes for Rivets and Bolts . Holes for rivets or bolts shall be 1/16 inch larger than their nominal diameter except ...
Page 780
... holes extending across the part in any straight or broken line shall be obtained by deducting from the gross width the sum of the diameters of all the holes in the chain and adding s2 / 4g for each gage space in the chain . In the cor ...
... holes extending across the part in any straight or broken line shall be obtained by deducting from the gross width the sum of the diameters of all the holes in the chain and adding s2 / 4g for each gage space in the chain . In the cor ...
Page 834
... holes . The holes are to be located in four rows spaced 1/4 inch centers with the rows spaced 1/4 inch . The holes are to be staggered in each row so that they are positioned halfway between the holes of the adjacent rows . This results ...
... holes . The holes are to be located in four rows spaced 1/4 inch centers with the rows spaced 1/4 inch . The holes are to be staggered in each row so that they are positioned halfway between the holes of the adjacent rows . This results ...
Other editions - View all
Common terms and phrases
½ inch adhesive allowable load apply average bending members Black knots bolt BUILDING CODE STANDARD Characteristics and limiting combinations compression members compressive strength concrete masonry units connector cross section design value diameter dimension Douglas fir E-rated eastern white pine edge end joints equivalent smaller exceed FACE WIDTH feet glued grading rules half the thickness holes inch wide Inner knots lams less limiting provisions localized cross grain lumber manufactured material maximum measured medium grain minimum modulus of elasticity moisture content mortar nominal occasional piece outer tension panel parallel percent permitted perpendicular pitch streaks pith plywood pounds per square procedures RED KNOTS requirements sample sapwood scarf joints seasoning checks shake shear slope of grain southern pine spaced species specified splits square inch stress surface Table tension laminations test specimens timber torn grain U.B.C. Standard Uniform Building Code veneer visually graded wane wide face wood failure