Building Standards: Uniform Building Code1985 - Building laws |
From inside the book
Results 1-3 of 61
Page 339
... nails and spikes , and to threaded , hardened steel nails and spikes which shall conform to the minimum sizes set forth in Table No. 25-17 - I . Nails , Staples and Spikes Sec . 25.1716 . ( a ) Steel Wire . Steel wire shall be of good ...
... nails and spikes , and to threaded , hardened steel nails and spikes which shall conform to the minimum sizes set forth in Table No. 25-17 - I . Nails , Staples and Spikes Sec . 25.1716 . ( a ) Steel Wire . Steel wire shall be of good ...
Page 341
... nails shall be plus or minus 10 percent of the nominal head diameter ( individual measurement ) . The difference in ... nails the difference in diameter across the long axis should not exceed that across the short axis by more than 10 ...
... nails shall be plus or minus 10 percent of the nominal head diameter ( individual measurement ) . The difference in ... nails the difference in diameter across the long axis should not exceed that across the short axis by more than 10 ...
Page 963
... Nails Sec . 43.306 . Core nails shall be cut nails of the clinch type or duck bill point type power - driven nails that clinch . For three - ply cores the nails shall be not less than 2 % inches nor more than 3 inches long . For two ...
... Nails Sec . 43.306 . Core nails shall be cut nails of the clinch type or duck bill point type power - driven nails that clinch . For three - ply cores the nails shall be not less than 2 % inches nor more than 3 inches long . For two ...
Other editions - View all
Common terms and phrases
accordance adhesive allowable apply average bending bolt bonding characteristics checks combinations compression conform connector containing continuous covers cross section depth determined diameter dimension direction distance Douglas fir edge end joints equal equivalent exceed failure feet firm fourth grade Group half heart heavy holes inch Inner knots laminations lams least length less light limited load lumber machine manufactured marked masonry material maximum measured medium methods moisture content nominal outer panel parallel percent permitted piece pine pitch plate plywood pockets pounds procedures production provisions requirements rings sample seasoning Select shake shear shown side sizes slope of grain southern pine spaced species specified splits square streaks strength stress Structural surface Table tension test specimens thickness third Type U.B.C. Standard Uniform Building Code units values veneer visually wane weight western wide face width wood Zone