... portion of the connector groove within the member and that portion of the bolt hole not within the connector groove , located at the critical plane . ( See Table No. 25-17 - A . ) If knots occur at the critical section , the cross ...
... portion of the connector groove within the member and that portion of the bolt hole not within the connector groove , located at the critical plane . ( See Table No. 25-17 - A . ) If knots occur at the critical section , the cross ...
Page 346
... portion . The larger figure in each range shall apply to screws of the greater diameters . ( c ) Insertion . The threaded portion of the screw shall be inserted in its lead hole by turning with a wrench , not by driving with a hammer ...
... portion . The larger figure in each range shall apply to screws of the greater diameters . ( c ) Insertion . The threaded portion of the screw shall be inserted in its lead hole by turning with a wrench , not by driving with a hammer ...
Page 839
... portion . ( b ) Grade B. The bend test specimen of Grade B shall stand being bent , at room temperature , in any direction through 180 degrees around one thickness of the material without cracking on the outside of the bend portion ...
... portion . ( b ) Grade B. The bend test specimen of Grade B shall stand being bent , at room temperature , in any direction through 180 degrees around one thickness of the material without cracking on the outside of the bend portion ...
Contents
CHAPTER | 7 |
Standard and Subject 1256 October 1979 of the Underwriters Laboratories | 14 |
CHAPTER | 26 |
Copyright | |
11 other sections not shown
Other editions - View all
Common terms and phrases
accordance adhesive allowable load apply average beams bending members Black knots bolt bonding BUILDING CODE STANDARD butt joints combinations compression compression members connector core cross section design value determined diameter dimensions Douglas fir E-rated eastern white pine edge end joints exceed FACE WIDTH feet fiber flange glue lines glued hem-fir holes inch wide Inner knots lag screw laminating grade lams length less limiting provisions localized cross grain lumber manufactured masonry material maximum measured medium grain minimum modulus of elasticity moisture content nails nominal outer tension panel parallel percent permitted perpendicular plies plywood pounds per square procedures requirements sample sapwood scarf joints seasoning checks shake shear shear strength slope of grain southern pine spaced specified splits square inch strength stress structural surface Table temperature tension laminations Tension Zone test specimens thermocouples timber U.B.C. Standard Uniform Building Code veneer visually graded wane wide face wood failure