Page 204
... shown for the outer tension lamina- tion . In addition to these , the general grading provisions in Item A apply ... shown in Item ( i ) , the clear wood at a cross section and slope of grain may be modified as shown in Items ( ii ) and ...
... shown for the outer tension lamina- tion . In addition to these , the general grading provisions in Item A apply ... shown in Item ( i ) , the clear wood at a cross section and slope of grain may be modified as shown in Items ( ii ) and ...
Page 426
... shown in Figures Nos . 25-19-2 and 25-19-3 . Shear Strength Sec . 25.1942 . ( a ) Moisture and Temperature Effects on Strength . 1. Prepare block shear specimens as described in Section 25.1930 . 2. Test the specimens for shear strength ...
... shown in Figures Nos . 25-19-2 and 25-19-3 . Shear Strength Sec . 25.1942 . ( a ) Moisture and Temperature Effects on Strength . 1. Prepare block shear specimens as described in Section 25.1930 . 2. Test the specimens for shear strength ...
Page 966
... shown in Figure No. 43-3-8 . Each upper corner shall be covered the same as bottom corners if a cap is not used for covering the top edge of the core . The bottom edge and the vertical edges of the core shall be covered with plates bent ...
... shown in Figure No. 43-3-8 . Each upper corner shall be covered the same as bottom corners if a cap is not used for covering the top edge of the core . The bottom edge and the vertical edges of the core shall be covered with plates bent ...
Other editions - View all
Common terms and phrases
½ inch adhesive allowable load apply average bending members Black knots bolt BUILDING CODE STANDARD Characteristics and limiting combinations compression members compressive strength concrete masonry units connector cross section design value diameter dimension Douglas fir E-rated eastern white pine edge end joints equivalent smaller exceed FACE WIDTH feet glued grading rules half the thickness holes inch wide Inner knots lams less limiting provisions localized cross grain lumber manufactured material maximum measured medium grain minimum modulus of elasticity moisture content mortar nominal occasional piece outer tension panel parallel percent permitted perpendicular pitch streaks pith plywood pounds per square procedures RED KNOTS requirements sample sapwood scarf joints seasoning checks shake shear slope of grain southern pine spaced species specified splits square inch stress surface Table tension laminations test specimens timber torn grain U.B.C. Standard Uniform Building Code veneer visually graded wane wide face wood failure