Page 213
... span E or by other methods of E measurement provided they are correlated with the long - span E. ( iii ) Identification . Each piece of MSR lumber used under this alternative provision shall be grade stamped with the appropriate stamp ...
... span E or by other methods of E measurement provided they are correlated with the long - span E. ( iii ) Identification . Each piece of MSR lumber used under this alternative provision shall be grade stamped with the appropriate stamp ...
Page 438
... span is the clear distance between supports . For sloping rafters the span is measured along the horizontal projection . Lumber Stresses Sec . 25.2103 . The use of the span tables requires reference to the list of single or repetitive ...
... span is the clear distance between supports . For sloping rafters the span is measured along the horizontal projection . Lumber Stresses Sec . 25.2103 . The use of the span tables requires reference to the list of single or repetitive ...
Page 677
... spans shown , multiply the live load of the shortest net span shown in the load table by the ( shortest net span plus .67 feet ) 2 , and divide by the ( actual net span plus .67 feet ) 2 . The live load shall not exceed the safe uniform ...
... spans shown , multiply the live load of the shortest net span shown in the load table by the ( shortest net span plus .67 feet ) 2 , and divide by the ( actual net span plus .67 feet ) 2 . The live load shall not exceed the safe uniform ...
Other editions - View all
Common terms and phrases
accordance adhesive allowable apply average bending bolt bonding characteristics checks combinations compression conform connector containing continuous covers cross section depth determined diameter dimension direction distance Douglas fir edge end joints equal equivalent exceed failure feet firm fourth grade Group half heart heavy holes inch Inner knots laminations lams least length less light limited load lumber machine manufactured marked masonry material maximum measured medium methods moisture content nominal outer panel parallel percent permitted piece pine pitch plate plywood pockets pounds procedures production provisions requirements rings sample seasoning Select shake shear shown side sizes slope of grain southern pine spaced species specified splits square streaks strength stress Structural surface Table tension test specimens thickness third Type U.B.C. Standard Uniform Building Code units values veneer visually wane weight western wide face width wood Zone