Page 76
... strength and stiffness values to a fiber strength in bending of the percentage indicated of that allowed for clear , straight - grained wood . 2-4 Inches Thick , 2-4 Inches Wide STRUCTURAL LIGHT FRAMING Grade Name ( and Abbreviation ) ...
... strength and stiffness values to a fiber strength in bending of the percentage indicated of that allowed for clear , straight - grained wood . 2-4 Inches Thick , 2-4 Inches Wide STRUCTURAL LIGHT FRAMING Grade Name ( and Abbreviation ) ...
Page 614
... strength test is deposited shall be recorded . To conform to the requirements of this standard , the average of all the strength tests representing each class of concrete shall be sufficient to ensure that the following require- ments ...
... strength test is deposited shall be recorded . To conform to the requirements of this standard , the average of all the strength tests representing each class of concrete shall be sufficient to ensure that the following require- ments ...
Page 618
... strength tests shall have values less than the specified strength , f'c , and the average of any six consecutive strength tests shall be equal to or greater than the specified strength . 2. For concrete in structures designed by the ...
... strength tests shall have values less than the specified strength , f'c , and the average of any six consecutive strength tests shall be equal to or greater than the specified strength . 2. For concrete in structures designed by the ...
Other editions - View all
Common terms and phrases
accordance adhesive allowable apply average bending bolt bonding characteristics checks combinations compression conform connector containing continuous covers cross section depth determined diameter dimension direction distance Douglas fir edge end joints equal equivalent exceed failure feet firm fourth grade Group half heart heavy holes inch Inner knots laminations lams least length less light limited load lumber machine manufactured marked masonry material maximum measured medium methods moisture content nominal outer panel parallel percent permitted piece pine pitch plate plywood pockets pounds procedures production provisions requirements rings sample seasoning Select shake shear shown side sizes slope of grain southern pine spaced species specified splits square streaks strength stress Structural surface Table tension test specimens thickness third Type U.B.C. Standard Uniform Building Code units values veneer visually wane weight western wide face width wood Zone