Uniform Building Code |
From inside the book
Results 1-3 of 81
Page 489
... inch in 12 inches for gravel surface or 2 inches to 12 inches for smooth or cap sheet surface shall be blind nailed through tin caps into the deck , wood nailers or wood insulation stops at not more than 18 inches on center to secure ...
... inch in 12 inches for gravel surface or 2 inches to 12 inches for smooth or cap sheet surface shall be blind nailed through tin caps into the deck , wood nailers or wood insulation stops at not more than 18 inches on center to secure ...
Page 595
... 12 - inch concrete slab above . " Thickness measured to bottom of steel form ... inches where limestone aggregate is used . ' Slab thickness over steel ... inches on center or 10 inches on center [ for channel spacing of 16 inches and 12 ...
... 12 - inch concrete slab above . " Thickness measured to bottom of steel form ... inches where limestone aggregate is used . ' Slab thickness over steel ... inches on center or 10 inches on center [ for channel spacing of 16 inches and 12 ...
Page 623
... inches ) Nails 3 PLANE OF FRAMING TABLE NO . 47 - G - APPLICATION OF SINGLE - PLY GYPSUM WALLBOARD LONG DIMENSION OF ... 12 1/2 Horizontal Perpendicular 24 7 12 Vertical Either Direction 24 8 12 Horizontal Either Direction 16 7 12 5 ...
... inches ) Nails 3 PLANE OF FRAMING TABLE NO . 47 - G - APPLICATION OF SINGLE - PLY GYPSUM WALLBOARD LONG DIMENSION OF ... 12 1/2 Horizontal Perpendicular 24 7 12 Vertical Either Direction 24 8 12 Horizontal Either Direction 16 7 12 5 ...
Contents
Effective Use of the Uniform Building Code | 20 |
Organization and Enforcement | 26 |
Part IIDefinitions and Abbreviations | 38 |
Copyright | |
92 other sections not shown
Other editions - View all
Common terms and phrases
allowable stress ALLOWABLE UNIT STRESSES applied approved bars beam bending bolts Building Official building or structure ceiling Code column compression compression members concrete conform dead load diameter diaphragms Division 1 Occupancies enclosure exceed exit exterior walls EXTREME FIBER Fire Zone flange flexural floor area frame gauge girders grade Group grout gypsum height installed joints joists lath length less live load located lumber masonry materials maximum metal minimum MODULUS OF ELASTICITY mortar nails noncombustible occupant load one-hour fire-resistive openings panel partitions percent permitted plaster plastic plywood portland cement pounds per square prestressing protected reinforcement resist roof rooms Select Structural shear stress shear walls sheathing slab space space frame span specified in Chapter specified in Section square feet square inch stairway steel strength studs surface Table tension tests thickness tion U.B.C. Standard values ventilation vertical water closet welds width wire wood yield strength